DYNACO DY 4000 Elektrisches Handbuch - Seite 9

Blättern Sie online oder laden Sie pdf Elektrisches Handbuch für Bedienfeld DYNACO DY 4000 herunter. DYNACO DY 4000 12 Seiten.

DYNACO DY 4000 Elektrisches Handbuch
Manual & Automatic Close Timers
4.0
Setting the Manual & Automatic Close Timers
4.1
Setting MC/PB Timer
DYNACO USA, INC,
The Dynalogix II has two automatic close timers. The first timer, MC/PB timer,
will count down after a activation is installed on terminal number 2 (most
commonly used for pull cords or pushbuttons). MC/PB timer also can be
turned on or off, making it manual operation or automatic operation simply by
assigning a countdown value to the timer. The second timer, AC/Loop timer,
will count down after a activation is installed on terminal 4 (most commonly
used are motion sensors and loops). If this timer is set to zero, the door will
come down after door reaches upper limit.
1. Press and release MC/PB Timer button on the Dynalogix II controller.
The display will change to: MC Delay_Time=##. See figure 4.1-1.
RUN
TIMERS
OPEN
JOG
UP/RESET
JOG
MC/PB
DOWN
CLOSE
TIMERS
MENU
Figure 4.1-1: MC/PB Timer
2. Use the Up and Down arrow buttons to change the countdown time to the
desired duration. The Dynalogix II will automatically save any changes that
are made. See figure 4.1-2.
RUN
TIMERS
OPEN
JOG
UP/RESET
JOG
MC/PB
DOWN
CLOSE
TIMERS
MENU
Figure 4.1-2: Raise/Lower Manual Timers
CLOSE
PROGRAM
AC/LOOP
ENTER
CLOSE
PROGRAM
AC/LOOP
ENTER
The Leader in Door Safety & Design
8
MC/PB
Timer
MESSAGE DISPLAY / COUNTER
MC Delay
Time=##
Increase
Setting
Decrease
Setting