3.
Connect the electrical wiring to the motor
according to the diagram below.
- Switching fan and luminaire on/off
together with one switch:
4.
Fix the fan to the ceiling using 4 screws.
5.
Replace the cover and protective grille.
Technical Information
Power input: 230v (must be connected to 12v
transformer supplied)
Maximum ventilation volume: 89m
Power consumption: 14W + 1W LED Lamp
Dimensions: W150 x H150 x D125mm
Warning
The Air-Star is supplied with an MR16 1 watt
LED bulb. This is the only bulb suitable for use
with this fan. Do not replace with any other
bulb as this will invalidate any warranty. Do not
exceed the stated wattage.
Maintenance
In the event of a fault, please check the in-line
fuse located inside the connection box.
Fan maintenance is to be performed only after
the fan is disconnected from the mains power
supply. Maintenance means periodic clearing
of the surfaces from dust and dirt.
In order to remove the fascia for maintenance,
please remove the small retaining screw and
gently prise the fascia away from the casing.
Care Instructions
All surfaces should be cleaned with diluted
detergent, i.e. washing up liquid, and a soft
cloth. Scourers and scouring agents should not
be used, as these may cause damage to the
surface of the product.
/hr (±5%)