EmerCom Technologies ETH004 Kurzanleitung - Seite 7
Blättern Sie online oder laden Sie pdf Kurzanleitung für Aufnahmegeräte EmerCom Technologies ETH004 herunter. EmerCom Technologies ETH004 11 Seiten. Ip interface analog telephone adaptor
3. Configuration:
3.1 Equipment
The ETH004 package contains:
1x ETH004 module (some pre-configuration done in factory)
1x 5V Plugin power adapter
1x Ethernet patch cable
In addition, you will need:
At least 1x EMC-60 – Emergency Hands-free Phone (or a handset)
Static IP address for ETH004 (optional – provided by building), otherwise run
in DHCP mode
IP Address of SIP server or ITSP details (provided by building)
Name, Authentication Password, and Authentication IP for SIP Extension
(provided by building)
Battery backed up power source
3.2 Set-up
1. Supply battery-backed up power to the ETH004 micro-USB connection
2. Connect the Ethernet port to the network router.
3. Open Web Browser on your computer and use the assigned IP address to
navigate to the Web UI.
o The IP address can also be found using the IVR voice prompt menu:
4. Enter the username and password. For administrator: user: admin,
password: admin. This will take you to the Device status window.
NOTE: The device has been pre-configured to operate with EMC-60
Connect a phone to Phone 1
Lift and press "***". You will hear "Enter the menu option".
Press "02" to hear the current IP address.
ETH004 User Guide
- 7 -