2GIG-FT1-345
FLOOD AND TEMPERATURE DETECTOR
INSTALLATION INSTRUCTIONS
The 2GIG-FT1-345 is a fully supervised, tamper protected one-way 345 MHz
sensor. It will monitor the ambient temperature and/or will detect a wet/dry flood
condition. The sensor reports wet/dry conditions and temperature to the panel.
Flood Conditions
Once the sensor probe detects the presence of water for three (3) minutes, the
integral transmitter will send a wet alarm transmission to the panel. The probe will
also send a restore (dry) report when the presence of liquid is no longer detected
by the flood probe for three (3) minutes. For flood reporting the sensor requires
the installation of the supplied external flood probe. The sensor is capable of
detecting clean or dirty fresh water, salt water, or tap water.
Temperature Conditions
Heat:
1. If the temperature is more than 95° F (35°C) for five (5) minutes, the sensor
will send a loop 2 transmission.
2. If the temperature is less than 95°F (35°C) for five (5) minutes, the sensor will
send a loop 2 clear.
Cold:
1. If the temperature is less than 41°F (5°C) for five (5) minutes, the sensor will
send a loop 3 transmission.
2. In the temperature is more than 41°F (5°C) for five (5) minutes, the sensor
will send a loop 3 clear.
Contents
Verify that the package includes the following:
• 1—2GIG Flood/Temperature Sensor
• 1—Sensor Mounting Plate
• 1—3V Lithium Battery ( Panasonic CR15H270 uninstalled)
• 3—3/8" Phillips Screws
• 1—Double Stick Tape Strip
• 1—Probe Mounting Plate
Installation Tools Required
• Phillips Screwdriver
Figure 1.Temperature/Flood Sensor Contents
B
A
C
D
A Double Stick Tape Strip
B Sensor Mounting Plate
C Probe Mounting Plate
D 3V Lithium Battery
E Phillips Screws (3/8")
F Flood Probe Cord
G Flood Probe
H Transmitter with Integral Temperature Sensor
Installing and Replacing Battery
Open Sensor Case as show in Figures 2 and 3.
Install or replace battery.
1 Copyright © 2015 Nortek Security & Control
G
F
H
E
Figure 2. Opening Sensor Case
Grip the base of the sensor case. Place thumb on tab and push down until sensor
case separates.
Figure 3. Separate Sensor Case
Figure 4. Installing New Battery
BATTERY
Installing a New Battery and System Programming
NOTE: Do not install battery until panel is in Sensor Programming Mode.
1. Place panel in Sensor Programming mode
2. Insert battery
3. Close sensor
Replacement Battery Installation:
NOTE: If battery has been previously installed
1. Remove battery and dispose of (meeting state regulations)
2. Wait two (2) seconds
3. Replace battery
4. Close sensor
Installing/Mounting Flood/Temperature Sensor
The 2GIG-FT1-345 Flood and Temperature Sensor includes two methods of
installation:
1. Double Stick Tape Installation (See Figure 5).
2. Screw/Mounting Plate Installation (See Figure 6).
It is strongly recommended that the Flood/Temperature Sensor be mounted using
screws (provided) and Mounting Plate (provided).
Figure 5. Double Stick Tape Mounting Sensor Mounting Plate
APPLY DOUBLE STICK
TAPE TO BACK OF
MOUNTING PLATE
FLOOD/
TEMPERATURE
SENSOR
MOUNTING
PLATE
1. PUSH DOWN ON
THUMB TAB.
2. PULL BACK PLATE
OFF OF COVER
REMOVE SENSOR
COVER FROM
SENSOR BASE
TEMPERATURE/
FLOOD SENSOR
BASE
BATTERY REMOVAL
AND/OR INSTALLATION
WALL
FIRST
PUSH
SENSOR
ONTO
MOUNTING
DOUBLE
PLATE
STICK
TABS
TAPE
THEN PUSH
STRIP
UP