CC908-RF(ES) WIRELESS THERMOSTAT
CC908-RF(ES) can replace most common residential thermostat and is designed to be used
with electric, gas or oil heating control system or cooling system.
Unlike ordinary single unit design thermostat, this unit is a new type of thermostat
separating the thermostat function into two units. Receiver socket and Remote control transmitter
CC908-TR. The Control Centre serves as user interface and temperature sensing/control. User can
put the control Centre nearby and can read/control the temperature of really the living area while
put the Receiver besides the heating or cooling system. The unit is linked by RF.
Power source ............................ Control Centre 2 AA batteries
Frequency band............................ 433 MHZ
Relay contact .............................. 230VAC 10A
Room temperature setting range.........5℃ to 35℃ (41℉ to 95℉)
Accuracy.................................... ±1℉ or ±0.5℃
Dimensions................................. Control Centre 115mm×90mm×28mm
Color......................................... White
 Can be placed anywhere in the home to detect and control the temperature of an area of the
user's choice. Not limited by power control wiring locations.
 Link with the Receiver via RF. Control distance 100M open site.
 Large LCD display
 The screen displays the set temperature and the room temperature also time simultaneously
 Permanent user setting and program setting retention during power loss
 Optional temperature display of Celsius or Fahrenheit scale
 Both Vacation mode and hold duration mode available for comfort and energy saving
 Optional programming Period: 7 individual day or Separate 5-day (weekday) and 1-day/1-day
(Saturday/Sunday) programming with 4 or 6 separate time/temperature periods per day.
 Display temperature recalibrates
 Low battery indication
 Anti-freezing protection
 Pump protection available
Installation and operation instructions
SPECIFICATION:
Receiver 230VAC±10% 50/60HZ
Receiver 126mm×68mm×47mm
FEATURE:
1