Connect the negative pole of the battery to the negative connection of the caravan mover unit.
Connect the positive terminal of the battery to the positive terminal of the caravan mover unit.
Use cables as prescribed in your caravan mover manual. It is recommended to use a minimum of 16 mm².
Use one red wire for the + and one black or blue wire for the -.
Never connect the battery in parallel to any other type of battery, including the wiring from the car.
Do not work on the LiFePO4 battery or the installation when it is still live. Only make changes to your electrical
installation carried out by qualified electricians.
After first use test all the connections for (over) heating. Repair or replace connections that have become
too hot.
Check the wiring and connections at least once a year. Immediately rectify defects such as loose
connections and burnt/melted cables.
System overview:
Figure 3. Wiring diagram
© 2021 EmergoPlus B.V.
CAFEFUL!
Observe the polarity of the battery and avoid short
circuits! Equipment whose polarity is incorrectly
connected can be irreparably damaged.
PAY ATTENTION!
Install a fuse and a main switch to the
power
circuit
according
regulations. Place the fuse as close as
possible to the + pole of the battery.
All rights reserved.
DOCUMENT: E09-X20&X30 V2.0-EN03_Handleiding
CAREFUL!
If bolts which are too long are used, the
connections will not get tight! This leads to
large contact resistances and can cause the
battery or equipment to spark or switch off.
to
local
WARNING!
Never connect the battery in parallel to another
battery, including the wiring from the car.
An X20 can be connected in parallel with another X20 battery.
Page 11 of 16
A = PowerXtreme X20/X30
B = Fuse
C = Main switch
D = Load
Date: 10-2-2021