TROUBLESHOOTING
Eliminate Flashing ISO legend and Quick Flashing Green, Quick Flashing Red ISO
LED problems:
1. Adjust the outdoor ontenno direction, keeping it away from indoor ontenno.
Restort booster.
2. Increase the vertical or horizontal distance between the outdoor antenna and
indoor ontenno. Restort booster.
. Use barriers such as walls to increase the isolation.
4. Change the indoor ontennd type to on antenna with o more directionol
ontenno pottern. Orient the indoor antenna and outdoor ontenno so they
point in opposite directions.
5. Reduce the booster's downlink goin using the manual goin controls. Keep
the uplink goin value and downlink goin value the some then restart the
booster.
Note: Uplink gdin must be equal to or not less than 5dB below the downlink goin,
to ovoid interference with the local corrier's cell site network.
Target: The ISO issues ore solved when the ISO LED is "Green" or "Slow Floshing
Green" or no floshing ISO legend.
Eliminate Flashing ALC legend and Quick Flashing Green, Quick Flashing Red Alarm
LED problems:
1. Adjust the ontennos' directions or locations to lower downlink received signal
level.
2. Slowly reduce the downlink goin using the Manual Goin Controls.
3. If the above methods don't work, reduce the booster's gain with on external
ottenuotor in line with the outdoor antenna or replace with lower goin
ontenno.
Target: The overlood issues are fixed when the Alarm LED is "Green" or "Slow
Floshing Green" or no floshing ALC legend. Please note that on "Green" LED
indicotion may result in smoller coverage area. This can be improved by
adjusting the outdoor antenna to receive 0 stronger signol.
Eliminate poor coverage problems when Power
legend on LCD and Alarm LED
is Green:
1. If the signal has not been improved, please check below:
- The weak downlink signol leads to the low output signal level. Change the