OFF: In some rare situations the ALC or ISO will not be able to compensate for an
oscillation condition or a downlink overload. When this happens the booster will
shut off in the affected band and the LCD "OFF" indicator will flash. Pressing the
"SET" button will turn on to help with troubleshooting and display which band or
bands are affected.
ISO flash
Band
UL
LTE700
---
P081900
———
---
AH82100
———
———
ALC flash
0FF flash
Band
UL
DL
Band
UL
LTE700
---
2
LTE700
0e11800
---
3
0611800
P081900
———
2
P081900
AHSZI00
#1082100
OFF OFF
OFF OFF
.
LED Status
LED
Status
Definition
Power LED
Alarm LED
ISO LED
Green
Off
Green
Slow Flashing
Green
Quick Flashing
Green
Quick Flashing
Red
Green
Slow Flashing
Green
Quick Flashing
Green
Quick Flashing
Red
Normal
DC power problem
Output power is
not maximum.
Full output power.
Output power is too high.
The booster automatically
shuts off for protection from
excessive downlink signal
from tower.
Check coverage, leave
as is if it's good; if the
coverage is poor,
please check the
Troubleshooting section
to get solutions.
Not working properly.
Please check the
Troubleshooting section
to get solutions.
No loopback or no self-oscillation. Working properly.
Slight loop back or self-oscillation.
Deep loop back or
self-oscillation.
The booster automatically
shuts off for protection due
to very severe self-oscillation.
11/19
Not working properly.
Please check the
Troubleshooting section
to get solutions.