ADEMCO VISTA-20PS Programmierhandbuch - Seite 2

Blättern Sie online oder laden Sie pdf Programmierhandbuch für Sicherheitssystem ADEMCO VISTA-20PS herunter. ADEMCO VISTA-20PS 17 Seiten.

ADEMCO VISTA-20PS Programmierhandbuch
TO ENTER PROGRAMMING MODE:
Local programming requires the use of an alpha keypad connected to the keypad terminals on the control.
A. POWER UP, then depress [ ✱ ] and [#] both at once, within 50 seconds of powering up (if ✱ 98 was used to exit program
mode, this method must be used to reenter program mode).
OR
B. Initially, key: Installer Code (4 + 1 + 1 + 2) plus 8 + 0 + 0.

DATA FIELD PROGRAMMING PROCEDURES

Task
Go to a Data Field
Entering Data
Review a Data Field
Deleting an Entry
INTERACTIVE MODE PROGRAMMING (∗56, ∗57, ∗58, ∗79, ∗80, ∗81, ∗82, ∗187)
Press [ ✱ ] + [Interactive Mode No.] (for example, ✱ 56). The alpha display keypad will display the first of a series of prompts
requesting entries.
Interactive Mode
✱ 56 Zone Programming
✱ 57 Function Key Programming
✱ 58 Zone Programming
(Expert mode)
✱ 79 Output Device Mapping
✱ 80 Output Programming
✱ 81 Zone List Programming
✱ 82 Alpha Programming
INITIALIZE DOWNLOAD and RESET DEFAULTS
✱ 96 Initializes download ID and subscriber account number.
✱ 97 Sets all data fields to original factory default values.

TO EXIT PROGRAMMING MODE:

✱ 98 Exits programming mode and prevents re-entry by: Installer Code + 8 + 0 + 0. If ✱ 98 is used to exit programming
mode, system must be powered down, and method A above used to enter the programming mode.
See field *88 for other *98 Program mode lockout options.
✱ 99 Exits programming mode and allows re-entry by: Installer Code + 8 + 0 + 0 or method 1 above.
Special Messages
OC = OPEN CIRCUIT (no communication between Keypad and Control).
EE or ENTRY ERROR = ERROR (invalid field number entered; re-enter valid field number).
After powering up, AC, dI (disabled) or Busy Standby and NOT READY will be displayed after approximately 4 seconds.
This will revert to a "Ready" message in approximately 1 minute, which allows PIRS, etc. to stabilize. You can bypass this
delay by pressing [#] + [0].
If E4 or E8 appears, more zones than the expansion units can handle have been programmed. Correct the programming
and then completely de-power and re-power the control to clear this indication and remove the disable indication.
www.PDF-Zoo.com
Procedure
Press [ ∗ ] + [Field Number], followed by the required entry.
When the desired field number appears, simply make the required entry. When the last entry for a
field is entered, the keypad beeps three times and automatically displays the next data field in
sequence.
If the number of digits that you need to enter in a data field is less than the maximum digits available
(for example, the phone number fields *41, *42), enter the desired data, then press [ ∗ ] to end the
entry. The next data field number is displayed.
Press [#] + [Field Number].
Data will be displayed for that field number. No changes will be accepted in this mode.
Press [ ∗ ] + [Field Number] + [ ∗ ]. (Applies only to fields ∗ 40–*46, *94, and pager programming fields)
Used to Program
Zone characteristics, report codes, alpha descriptors, and serial numbers for 5800 RF
transmitters.
Unlabeled keypad keys (known as ABCD keys) for special functions
Same options as *56 mode, but with fewer prompts. Intended for those familiar with
this type of programming, otherwise *56 mode is recommended.
Assign module addresses and map individual relays/powerline carrier devices
4229 or 4204 Relay modules, Powerline Carrier devices, or on-board triggers
Zone Lists for relay/powerline carrier activation, chime zones, pager zones, etc.
Zone alpha descriptors
– 2 –