Automatic Technology GDO-6 EasyRoller Benutzerhandbuch - Seite 9
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Garagentoröffner Automatic Technology GDO-6 EasyRoller herunter. Automatic Technology GDO-6 EasyRoller 20 Seiten. Rolling door openers
Auch für Automatic Technology GDO-6 EasyRoller: Einbauanleitung (2 seiten), Kurzbedienungsanleitung (6 seiten)
7. Safety Testing
7.1 Test the Close Cycle
a. Press the transmitter to open the door.
b. Place a piece of timber approximately 40mm high
on the floor directly under the door
c. Press the programmed transmitter to close door.
d. The door should strike the object and re-open.
7.2 Testing the Open Cycle
a. Press the transmitter to close the door
b. Press again to open the door.
c. When the door reaches approximately half way,
firmly grab the door's bottom rail -
should stop.
If the door does not reverse readily when closing, or
stop when opening, put the door into manual and
contact your door professional immediately for a
door service.
7.3 Test the Manual Door Operation
Periodically disengage the opener (Section 6.1) and
manually operate the door. The door must be smooth
to operate by hand. The force required on the bottom
rail should not exceed 15 kg.
7.4 Setting the PET Mode position
When activated, PET mode drives the door to the
preset position from the close position.
a. Drive and stop the door at the deisred PET mode
open position by pressing the transmitter button
coded for Open/Stop/Close operation.
b. Press and hold the OPEN button on the opener for
six (6) seconds until the OPEN and CLOSE LED's
are lit to record the new PET position.
To program a transmitter button to operate PET mode
refer to 8.3 Code Transmitter for PET Mode.
Periodically test if a PET mode button is pressed, while
the door is moving, the door will stop or when the
door is in the PET position, the door will close.
GDO-6 EasyRoller
(Fig 7.1)
(Fig 7.2)
(Fig.
7.1).
the door
Fig. 7.1
Fig. 7.2
®
Home Owner's Manual
CAUTION: Take care when
completing a safety test. Failure
to follow this warning can result
in serious personal injury and/or
property damage.
WARNING! If the door is closing
and is unable to re-open when
obstructed, discontinue use.
Do not use a door with faulty
obstruction sensing. Contact your
door professional for support.
Select the button on
the transmitter that has
been programmed to
operate the door.
If transmitter is not programmed,
Refer to Section 8 to program
transmitter.
40mm
9