GAI-Tronics 10959-903 Handbuch - Seite 11

Blättern Sie online oder laden Sie pdf Handbuch für Aufnahmegeräte GAI-Tronics 10959-903 herunter. GAI-Tronics 10959-903 20 Seiten. Audio control center hard-wired system interconnection w/ radio access
Auch für GAI-Tronics 10959-903: Handbuch (6 seiten)

Models 10959-903 and 10959-904 Wall-Mount Audio Messenger Interface

Configuration

Opening the Unit

1. Loosen the four screws on the front cover.
2. Open the hinged front cover of the enclosure and turn it to the left.
Figure 4. AMI (open with connections, adjustments, and PCBAs labeled)

600-Ohm Line Termination Jumper Setting

Terminate the 600-ohm audio lines with 600 ohms for impedance matching. Use jumper P5, located on
the termination board to enable/disable impedance matching on the 600-ohm audio line connections (see
Figure 4 and Table 5).
Jumper
Output
TB3-1, 2
P5
600 ohms
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-442D.docx
10/18
Table 5. Termination PCBA—P5 Jumper Function
Position
Function
1-2
600-ohm resistor connected (ADVANCE position)
2-3
default: unterminated
Pub. 42004-442D
Page 9 of 17