Installation Guide
iCLASS Reader Models bio500, RWKL550 & RWKLB575
4 – Keypad Reader Mounting
1. Slide the reader onto the short back plate, ensuring
that the tongue of the backplate is located in the slot
at the top of the reader and retain with a screw.
5- Connecting
Serial Port
8 Pin Terminal
Function
1
Ground
2
Y / RS-232 TX
3
Z
4
Ground
5
RS485B / RS-232 RX
6
RS-485A
7
Ground
8
DC+
1
Optional Connections
2
Drain wire can be used for data return line when a separate power supply is used.
3
+DC, Return & Drain wires are common between the Wiegand and Serial Ports.
6- Testing
A.
Turn Power On – Watch the sign-on LED and hear the speaker tone sequences.
B.
Read Card – Present a valid card to the reader and verify the visual and audio feedbacks.
7- Upgrading an RWKL550
Reverse installation step 4 in order to remove the reader from the backplate.
Replace short backplate with a long backplate and follow the Biometric Reader Mounting instruction, steps 1-3.

Optional Features

RS232/485 interface/Host Mode - for applications requiring a serial link. See Protocol Document 6090-902 for information
Configuration Options - Configure LED, Speaker, and other features. See How To Order Guide or iCLASS Application Note for details
Hold Input – when asserted, this line either buffers a card read or disables a card read until released, as configured.
FCC WARNING:
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause undesired operation. For proper regulatory compliance, the drain wire
should be disconnected at the power supply end of the cable. The reader is intended to be powered from a limited power source output of a previously certified
power supply. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
An ASSA ABLOY Group company
_____________________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
Web page - www.hidcorp.com e-mail – [email protected]
iCLASS Biometric/LCD keypad Reader Install Manual 6096-901 Rev A.2
Wiegand Port
10 Pin Terminal
Color-coded Pigtail
10
Violet
9
Blue
8
Yellow
7
Drain
6
Brown
5
Orange
4
White
3
Green
2
Black
1
Red
Page 3 of 4
Function
Actuator Signal
1
Hold
1
Speaker
2
Shield Ground
1
Red LED
1
Green LED
Data 1
Data 0
Ground
3
+DC (9-12 VDC)
ASSA ABLOY