6 Electrical connection

The unit must be connected by a qualified electrician.
The national and international regulations for the installation of electrical
equipment must be adhered to.
cULus - Class 2 source required.
► Disconnect power.
► Connect the unit as follows:
LED1
n.c. = not connected
1: Connection Ub and output signals (operation as 2-wire unit)
2: Connection Ub and output signals (operation as 3-wire unit)
3: Connection of a 2-wire measuring probe;
links between 1 / 2 and 3 / 4.
4: Connection of a 4-wire measuring probe.
LED 1: lit in case of operation as 3-wire unit.
LED 2: lit in case of a load on the analog output.