Automationdirect.com Productivity 1000 P1-04RTD Handbuch - Seite 6

Blättern Sie online oder laden Sie pdf Handbuch für E/A-Systeme Automationdirect.com Productivity 1000 P1-04RTD herunter. Automationdirect.com Productivity 1000 P1-04RTD 8 Seiten. Analog input

Automationdirect.com Productivity 1000 P1-04RTD Handbuch

Resistance Input Specifications

Internal Resolution
Resistance Input Ranges
and Resolution
Accuracy vs Temperature
Linearity Error (end to end)
Maximum Inaccuracy

Diagnostics

Module Diagnostics Failure
Module Not Ready
Channel Burn-out (RTD only)
Under-range (RTD only)
Over-range
6
www.productivity1000.com
16-bit, 0.0015% of full scale range in ohms
0 – 10,000 :
Resolution 1:
0 – 6,250 :
Resolution 0.1 :
0 – 3,125 :
Resolution 0.1 :
0 – 1,562.5 :
Resolution 0.1 :
0 – 781.25 :
Resolution 0.1 :
0 – 390.625 :
Resolution 0.01 :
0 – 195.3125 :
Resolution 0.01 :
±25ppm per °C (maximum)
±0.03% 16.7 Hz, ±0.06% 470Hz of full scale range
maximum at 25°C, Monotonic with no missing
codes
±0.10% of full scale range
1 bit per module
1 bit per module
1 bit per channel
1 bit per channel
1 bit per channel
Tech Support 770-844-4200