BGAN SATELLITE | INSTALLATION & ANTENNA ORIENTATION
HOW TO CONFIGURE BGAN COMMUNICATION IN ATLAS
1. Open the corresponding data logger in Atlas and click on "Site Settings"
2. Click on the "Communication" on the left-hand menu and select BGAN in the "Connection type" section.
3. Type the IP address associated to SIM-SAT and "950" in TCP Port.
TESTS IN CASE OF NOT BEING ABLE TO COMMUNICATE & TO CHECK THE CORRECT CONFIGURATION
There are two different points to test:
A. Moxa NPORT 5110 - Orbit data logger
To test the communication with the data logger through a Moxa, previously configured for working with a BGAN, the
following steps must be carried out:
1. Connect Moxa to a laptop.
2. Put an IP address on the laptop in the same range as the Moxa. The Ip configured in the Moxa, previously configured
for working with a BGAN, should be 192.168.128.101. Therefore, the laptop should have, for example, the IP address
192.168.128.150 with the network mask 255.255.255.0.
For more information please contact [email protected]
or visit our website www.kintech-engineering.com