Hidro-Water ZENIT Handbuch für Benutzer und Installateure - Seite 4

Blättern Sie online oder laden Sie pdf Handbuch für Benutzer und Installateure für Water Filtration Systems Hidro-Water ZENIT herunter. Hidro-Water ZENIT 15 Seiten. Residential reverse osmosis

Hidro-Water ZENIT Handbuch für Benutzer und Installateure

4.- INSTALLATION

The system can be installed anywhere in the residence where there is a water input,
a drain for concentrate, a 220 – 240 V socket within a metre and sufficient space to be
located. The most common place is under the kitchen sink. The installation should be
carried out by qualified personnel.

4.1.- Faucet installation (Figure-3)

a. Choose the location on the counter
where you want to install the faucet.
b.
Use a drill with a 12mm bit to make a
necessary sized hole to put the faucet.
c. Fit the faucet in the hole as indicated
in the picture using a box spanner (our
reference: OI-0207-128 not supplied
with system) or a wrench to adjust it
tightening the nut.
4.2.- Water inlet installation (Figure-8 & Figure-9)
The water supply input consists of two parts; a brass ball valve (Figure-9) and an
adaptor (Figure-8). The brass ball valve must be screwed to the adaptor using sufficient
Teflon on its thread, as shown in the picture below.
a.
Turn off the water supply at the point where you are installing the osmosis system.
b.
The water supply input is designed to be used with hoses with a ⅜" connection.
Insert the water feed adapter with the brass ball valve between the cold water supply
and the hose. (Never install on the hot water connection as the osmosis system will be
damaged). Make sure that the brass ball valve is closed.
Adapter
Connect 3/8" hose
Place
teflon
6
Connect to
water supply
Brass ball
valve
Connnect to the
osmosis system
with 3/8" tubing
MA-ES-RO-ZENIT_RO-0236-02_FL_20_V02

4.3.- Drain clamp installation (Figure-6)

a. The drain clamp is designed to adjust the sealing
drainpipe to 1 ½".
b. The drain clamp should always be installed above
the U-bend (before it) and in the case of a horizontal
drainpipe, install it above (at the top). Do not install
it near to the waste outlet as it could clog the
drainpipe.
c. Drill a 6mm hole in the drainpipe.
d. Align the clamp hole with the hole in the drainpipe
and carefully tighten the screws on the clamp until
it is fixed into place. Do not over tighten.

4.4.- Membranes installation (Figure-2)

To fit the membranes (Figure-2) in the membrane housings correctly, proceed as
follows:
a. Take off the right-hand-side cover of the ZENIT osmosis system (looking the system
from the front). To do so, you must unscrew the screws at the corners of that side
cover, having previously removed the protective caps that hide them, as shown in
the picture below.
b. Remove the membrane housings from their clamps. Remove the safety clips of
the inlet elbows and release the tube as shows the picture.
MA-ES-RO-ZENIT_RO-0236-02_FL_20_V02
7