Automationdirect.com Stride SE3-SW5U-N67-T Handbuch

Blättern Sie online oder laden Sie pdf Handbuch für Schalter Automationdirect.com Stride SE3-SW5U-N67-T herunter. Automationdirect.com Stride SE3-SW5U-N67-T 2 Seiten. Ip67 rated industrial unmanaged ethernet switches

®
S
®
tride
u
nmanagEd
Stride SE3 Unmanaged IP67 Models
M12
Part Number
10/100Tx Ethernet Ports
SE3-SW5U-N67-T
5
Power Details
Power Connection
Dual DC power inputs through M12 5-pin A-coded male connector
Input Voltage
Class 2 power supply: 12–48 VDC redundant power inputs
Reverse Power Protection
System Power Consumption
Relay Contact
M12 Ethernet Ports
10/100BaseT Ports
Ethernet Compliance
IEEE 802.3i, 802.3u, 802.3x for 10/100 Ethernet
Auto-Crossover
Yes, allows you to use straight-through or crossover wired cables
Auto-Sensing Operation
Auto-Negotiating Speed
Flow Control
IEEE 802.3x flow control, back pressure flow control
Cable Requirements
Twisted pair (Cat5e or better, shielded recommended)
Max. Cable Distance
Note: M12 caps need to be used on open (disconnected) ports.
Replacement caps (Part # ZP-JBH-CAP) are available from AutomationDirect.com
SE3 S
EriES
E
Operating
Temperature
-40 to +75°C [-40 to 167°F]
Yes
0.5 W
No
M12, female, D-coding, 4-pin
Yes, full and half duplex
Yes
100m [328ft]
iP67 r
atEd
S
thErnEt
witchES
N
:
ote
dowNload user maNual
a
area of
utomatioN
Processing Type
Devices Supported
MAC Addresses
Memory Buffer
Packet Forwarding Rate
Storage Temperature Range
Humidity (Non-Condensing)
Environmental Air
Vibration, Shock & Freefall
EMI Emissions
CE EN55035/EN61000-6-2 Class A: IEC61000-4-2 (ESD), IEC61000-4-3 (RS), IEC61000-
EMS
RoHS
Packaging and Protection
Agency Approvals
LED
State
On
PWR
Off
Indicates that there is a proper Ethernet connection (link) between the port and another
On
Ethernet Port
Indicates that there is a proper Ethernet connection (link) between the port and another
Blinking
LINK/ACT
Indicates that there is not a proper Ethernet connection (link) between the port and another
Off
1
3505 HUTCHINSON ROAD
CUMMING, GA 30040-5860, USA
i
nduStrial
se3-user-m
from the
d
.
irect
com for additioNal details
RoHS
RoHS Compliant
General Specifications
Store and forward
All IEEE 802.3 compliant devices are supported
1K
448Kbits
14.88 Kpps for Ethernet ports
148.8 Kpps for Fast Ethernet ports
-40 to +85 °C (-40 to +185 °F)
5 to 95% RH
No corrosive gases permitted
IEC60068-2-6, -27, -32
FCC Part 15 Subpart B Class A, CE EN55032/EN61000-6-4 Class A
4-4 (EFT), IEC61000-4-5 (Surge), IEC61000-4-6 (CS), IEC61000-4-8 (Magnetic Field)
RoHS (Pb free) compliant
Plastic case, IP67
FCC, CE, UL 61010-1, 61010-2-201
Front Panel LEDs
Description
Power input 1 or 2 is connected and operational
Power input 1 and 2 are both inactive
Ethernet device, but no communications activity is detected
Ethernet device, and that there is communications activity
Ethernet device. Make sure that each end of the cable has been plugged in securely.
P
m
roduct
aNuals
.