Dynamic Engineering IP-CF Benutzerhandbuch - Seite 11

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Kontrolleinheit Dynamic Engineering IP-CF herunter. Dynamic Engineering IP-CF 20 Seiten. Industrypack-compactflash adapter ip module

CompactFLASH internal registers

ip_cf_data
0x40 // compact flash read/write data pointer
ip_cf_f_err
0x42 // compact flash write feature/read error
ip_cf_sec_cnt
0x44 // compact flash read/write sector count pointer
ip_cf_sec_num
0x46 // compact flash read/write sector number pointer
iip_cf_cyl_l
0x48 // compact flash read/write cylinder number low pointer
ip_cf_cyl_h
0x4a // compact flash read/write cylinder number high pointer
ip_cf_sch
0x4c // compact flash read/write select card, head pointer
ip_cf_cmd_stat
0x4e // compact flash write command/read status pointer
ip_cf_cntl_as
0x5c // compact flash write control/read alt status pointer
Please refer to the CompactFLASH manuals for bit-map information.
E m b e d d e d
S o l u t i o n s
P g
1 1
o f
2 0