Automess 6150AD Technisches Handbuch - Seite 7
Blättern Sie online oder laden Sie pdf Technisches Handbuch für Kabel und Anschlüsse Automess 6150AD herunter. Automess 6150AD 7 Seiten. Dose rate meter probe connector
06/2003
2.3 4.75V
This section describes line and load characteristics of the 4.75V output which may be used to supply
external devices. As will be shown, up to 50 mA may be drawn from this output. This seems a reasonable
limit when keeping in mind that battery life with an external device should still amount to several hours.
The 4.75V output voltage is generated inside the 6150AD out of the battery voltage by means of a
switched regulator. It is individually tested in serial production to be in the range of 4.65V to 4.90V with a
typical value of 4.75V (at an input battery voltage of 7.0V).
U out
5.0
5.5
6.0
7.0
8.0
9.0
9.5
Note that at input battery voltages below 5.5 volts the 6150AD will issue battery warning.
Appendix with »Data Inputs« section is only supplied on special request.
Daimlerstrasse 27
D-68526 Ladenburg
Technical Manual 6150AD Probe Connector
I out
RL
4.75V
GND
no load
U
U
in
out
V
V
4.782
4.785
4.789
4.795
4.801
4.807
4.810
End of »Data Outputs« section.
Telefon +49(0)6203-9503-00 http://www.automess.de
Telefax +49(0)6203-9503-29 eMail: [email protected]
6150 AD
RL = 82.5 Ohm
I
U
in
out
mA
V
52.0
4.320
55.0
4.651
52.5
4.683
46.5
4.724
42.0
4.744
38.0
4.758
37.0
4.765
I
in
U in
I
efficiency
out
mA
%
52.4
87
56.4
87
56.8
84
57.3
83
57.5
81
57.7
80
57.8
78
USt.-ID-Nr. / VAT ID No.