Autometers Systems IC 970 Installations- und Betriebshandbuch - Seite 12
Blättern Sie online oder laden Sie pdf Installations- und Betriebshandbuch für Messgeräte Autometers Systems IC 970 herunter. Autometers Systems IC 970 12 Seiten.
Functions
Supplied
Function 09 -
Min/Max Volts
Function 10 -
Min/Max Amps
As Standard
Function 11 -
Min Max Neutral Amps
Function 12 -
Peak Maximum Demand
Function 13 -
C.T and N.T current transformer setting
Function 21 -
Pulse value
Function 22 -
Pulse Duration
Function 30 -
Display contrast
Function 31 -
Back light Duration
Function 50 -
Connection details
Function 51 -
Relay test mode
Function 52 -
Binar y switch positions
Physical
Dimensions (mm)
W96mm x H96mm x D 89mm (with comms module 103mm). Weight with communication module
and fixing clips: 0.64 k ilos. Pack ing weight individually boxed in polyfoam box: 0.65 k ilos
Maintenance and service
Field Service Considerations
In the unlikely event that a unit should fail, it will generally be ser viced by exchanging the unit
for a replacement unit. The initial installation should be done in a way which makes this as
convenient as possible.
1. I t is good practice that a current transformer shor ting block is fitted, this enables the meter to
be disconnected without open circuiting the current transformers. The shor ting block should be
wired so that the protective relays are not affected.
2. All wiring should be routed to allow easy removal of the connection to the terminals.
Disconnect From Supply
A suitable isolator for both voltage and current terminals shall be included in the wiring
installation, close to the meter with easy access and marked as the meters disconnect device.
If the equipment is used in a manner not specified by the manufacturer the protection provided
by the equipment may be impaired. Current measuring terminals are not intended to be
connected to voltages to ear th above 50Vac.
Per formance Characteristics - Typical load cur ve with balanced load at 50 Hz
0.4
0.3
0.246
0.223
0.189
0.2
0.102
0.1
0.068
0.048
0
0
1
2
22
Reset to Zero
Reset to Zero
Reset to Zero
Reset to Zero
Programmable
Programmable
Programmable
Programmable
Programmable
View only
View only
View only
Pf 0.5L
Pf 1.0
0.105
0.069
0.055
0.046
3
4
5
Amps
Dedicated customer service
Customer care is the cornerstone of the company 's success. A positive ser vice policy is obser ved
throughout ever y specialist area of operation.
The personal involvement of all the directors at ever y level, a highly trained and motivated staff,
fully computerised systems and in depth stock holding combine to provide a level of ser vice
which has earned the appreciation of customers across the spectrum of the UK and overseas
markets. Computerised distribution systems are geared to a consistent 24 hour despatch of
products, with 20 minute despatch being possible in response to urgent demand for small orders.
Product range
Metering and monitoring equipment ranges from single phase and Polyphase kWh
electromechanical meters to a sophisticated range of fully programmable information centres.
Also available are Electronic Meters, Panel Mounted Meters, Maximum Demand Meters, DIN Rail
Meters and Current Transformers.
CE Approval.
The IC 970 has been fully examined and tested in accordance with the standards listed and meets
the specified requirements defined in BS EN 61326:1997 inc A1, A2, A3 - Electrical equipment for
measurement, control and laborator y use - EMC requirements.
1. BS EN 61326:1997 inc. A1, A2 & A3
2. BS EN 61326:1997 inc. A1, A2 & A3
3. BS EN 61000-4-2:1995 inc. A1 & A2
4. BS EN 61000-4-3:2002 inc. A1 & A2
5. BS EN 61000-4-4:1995 inc. A1 & A3
Safety Standards: BS EN 61010-1:2001
Impor tant.
The attention of the specifier, purchaser, installer or user is drawn to special measures and
limitations to use which must be obser ved when these products are taken into ser vice to
maintain compliance with the CE directives. Details of these special measures and limitations
of use are available from HMSO.
REF: IEC 1000-5-1(BS195/210788DC) IEC 1000-5-2 (BS 195/214642DC)
IEC 10000-5-6 (BS 195/210789DC).
WARNING DO NOT MEGGAR TEST
6
Conducted Emissions
Radiated Electricity Field Emissions
Electromagnetic Compatibility
Electromagnetic Compatibility
Electromagnetic Compatibility
23