WALL ACCESS HOLE
SMOKE
DETECTOR
SENSOR
Figure 5. Install Smoke Detector Sensor between Wall and Moun ng Bracket
Place the smoke detector sensor where the exis ng moun ng bracket was
located. Make sure the wire/wiretaps are inserted through the center opening of
the smoke detector moun ng bracket.
Place the exis ng smoke detector moun ng bracket on top of smoke detector
sensor. Align the smoke detector sensor and the smoke detector moun ng
bracket and replace the two screws used to hold the bracket in place. Tighten all
screws down.
✓ NOTE: It is suggested that the smoke detector sensor LEDs be oriented towards
the bo om or in a manner that allows the LEDs on the unit to be visible.
EXISTING
POWER
PIGTAIL
MOUNT BRACKET
WITH LED'S AT BOTTOM
Figure 6. Wiretaps/Wires, & Pigtail through Center
1. PLACE WIRE
INTO
WIRETAP.
Figure 7. Crimping Wiretaps onto Wires
YEL/YEL OR
YEL/ORANGE
EXISTING
WIRETAPS (3)
POWER
CRIMPED
PIGTAIL
TO PRIMARY
CIRCUIT WIRES
Figure 8. Wiretap Connec ons
2 Copyright © 2016 Nortek Security & Control
EXISTING
POWER
PIGTAIL
WIRETAPS (3)
(NOT CONNECTED)
EXISTING SMOKE DETECTOR
MOUNTING BRACKET
SMOKE
DETECTOR
SENSOR
EXISTING
SMOKE
DETECTOR
MOUNTING
BRACKET
WIRETAPS (3)
(NOT CONNECTED)
2. HINGE WIRETAP
UP AND OVER
WIRE STRAND
3. CRIMP
WIRETAP WITH
PLIERS
PRIMARY POWER
WIRING
BLK/BLK (110VAC)
WHT/WHT (NEUTRAL)
WIRING CODE:
• BLACK TO BLACK (120 VAC)
• WHITE TO WHITE (NEUTRAL)
• YELLOW TO YELLOW OR
ORANGE (INTERCONNECT)
Wiring the Connections
Before connec ng the wires from the smoke detector sensor, iden fy the (+) line
(hot) 120VAC wire and the neutral wire. Usually the (+) line (hot) 120VAC wire
will be black and the neutral wire white. Use a voltmeter or voltage sensor to
verify that the proper wires are selected. You may need to reconnect power to the
electrical circuit powering the interconnected hardwired smoke detectors in order
to do this (Figure 8).
WARNING: Remember to disconnect or shut off electrical power to the
interconnected hardwired smoke detector if it was powered on in the previous
step to iden fy the 120VAC wires.
Use an electrician's linesman plier or equivalent tool (See Figure 8) and using the
installed wiretaps on the device, crimp the wiretap with the black wire onto the
120VAC line (hot) wire.
✓ NOTE: Wiretaps must be used on a sec on of stranded wire. This is typically
located between the connector to the smoke detector and the wire nut.
The wiretap with the yellow wire should be a ached to the wire lead connected
to the interconnect wire of the smoke detector. This wire is typically yellow or
orange.
Once all (3) three wiretaps have been installed (Figure 8), rea ach the electrical
wire pigtail to the back of the smoke detector unit and mount the smoke detector
on the moun ng base (Refer to Figure 3).
Installing the Back-Up Battery
CO
MOVE TO
FRESH AIR
First Alert
First Alert
SMOKE AND CARBON
MONOXIDE ALARM
SMOKE
Figure 9. Installing Back-up Ba ery
WARNING: Ensure that the smoke detector sensor has been wired correctly.
Damage to the smoke detector sensor may occur if the 120 VAC line (hot) wire
neutral wire are reversed. The unit may fail to func on properly if incorrectly
wired.
Turn on or reconnect power to the primary electrical circuit that powers the
interconnected hardwired smoke detector system. The device should now power
on.
Use a fl at bladed tool, slide out the ba ery tray that holds the backup ba ery.
Insert a CR2032A ba ery (included) into the ba ery slot. Slide the ba ery tray
back into the device (Figure 9).
✓ NOTE: Orient the (+) ba ery terminal up so that it is visible when facing the unit.
Programming the Sensor
Follow the instruc ons on how to program a sensor into a compa ble 2GIG control
panel. See the 2GIG control panel's Installa on & Programming Guide for more
informa on on how to learn a sensor into the control panel.
The device should learn in as a Loop 1 sensor device. Use a small paper clip or other
sharp object and carefully insert into the learn/test bu on hole. This will send
out an alarm transmission ID so the the sensor can be learned into a compa ble
control panel or can be used to test that the transmi er is working properly.
Replacing the Battery
If the compa ble control panel shows that this sensor has a low ba ery, the
backup ba ery may need to be replaced.
Use a fl at headed screw driver or other tool to slide the ba ery tray out of the
device. Remove the ba ery from the tray and replace with a new CR2032A
ba ery. Slide the ba ery tray back into the unit, making sure that the tray is fully
inserted into the unit.
✓ NOTE: Use Panasonic CR2032A ba eries or equivalent. Use of another ba ery
may damage or nega vely aff ect the opera on of the device.
End-of-Life
The Smoke Detector Sensor does not have an End-of-Life (EOL), however the
smoke detector(s) that this device monitors may have an EOL condi on. Follow
the owner's manual for the smoke detector regarding instruc ons on proper
smoke detector EOL condi ons.