Autonics SFC-R212 Handbuch - Seite 10

Blättern Sie online oder laden Sie pdf Handbuch für Controller Autonics SFC-R212 herunter. Autonics SFC-R212 13 Seiten. Safety controllers / safety relay unit
Auch für Autonics SFC-R212: Handbuch (13 seiten)

Autonics SFC-R212 Handbuch
Connection Examples 4
■ Basic unit-Safety emergency stop switch, Non-contact door switch unit-Safety non-contact door switch
Connections
Safety controller: Basic unit SFC Series
Safety emergency stop button switch: SF2ER Series
Push button switch (from Annex C of ISO 13849-1)
Contactor of rated load (from Annex C of ISO 13849-1)
Safety controller: Non-contact door switch unit SFC-N Series
Push button switch (from Annex C of ISO 13849-1)
Safety light curtain: SFL / SFLA Series
Safety non-contact door switch: SFN Series
Contactor of rated load (from Annex C of ISO 13849-1)
Safety controller: Basic unit
• Operation timing chart
Safety controller: Basic unit
Safety emergency stop switch SW1
Start switch SW2
MC1, MC2 b contact
MC1, MC2 a contact
S14, S24
M1 Rotation of motor
Safety controller: Non-contact door switch unit
Logic connections input M61
Safety light curtain SW3
Safety non-contact door switch SW4
MC3, MC4 b contact
MC3, MC4 a contact
Rotation of M2 motor
• For more information on detailed wiring for safety non-contact door switch (SFN Series), refer to the "
• For more information on wiring and detailed settings for safety light curtain (SFL/SFLA Series), refer to "
• The control output of the safety light curtain (SFL(A) series) is based on the PNP output.
• When you use the logic input (M61, M62), set the switch of the logic (AND) input (SW1, SW2) to ON.
• Set the switches for off-delay time on the front and back of the non-contact switch unit to the same.
Start
PL/Safety category
Manual
PLd/Cat.3 equivalent
Auto
Power
Safety Input 1
Safety Input 2
Feedback
Start Input
Auxiliary
PLC etc.
Output
Safety
Output
SW1: Safety emergency stop switch
SW2: Start switch
SW3: Safety light curtain
SW4: Safety non-contact door switch
MC1 to MC4: Contactor
M1, M2: 3-phase motor
Power
Safety Input 1
Safety Input 2
Feedback
Start
Input
Auxiliary
Output
Logic Input
Safety
Output
Safety controller: Non-contact door switch unit
Instruction manual for SFN
."
SFL/SFLA user manual.
"
Expansion
Output
Actuator
White
Black
SFN Series
Non-Contact
Safety Non-
Door Switch
Brown
Contact Door
Input
Switch
Blue
PLC etc.
Motor
Controller
Control Signal