Autonics PSAN-LV01CPH Series Handbuch - Seite 6
Blättern Sie online oder laden Sie pdf Handbuch für Messgeräte Autonics PSAN-LV01CPH Series herunter. Autonics PSAN-LV01CPH Series 13 Seiten. Small size, 1/2,000 resolution connector type digital pressure sensor
Auch für Autonics PSAN-LV01CPH Series: Handbuch (2 seiten)
Zero point adjustment
1
1. In state of atmospheric pressure during RUN mode,
press
key and
key at the same time for over
1sec.
2. When the zero-point adjustment is completed, it will
display
and return to RUN mode automatically.
※ Please execute zero-point adjustment regularly.
Parameter setting
1. It is able to set pressure unit, display resolution, output operation mode, output type, Response time, analog output
scale, Hold/Auto shift and key lock setting in parameter setting mode.
2. If the key lock is set (lock1 or lock2), unlock the key lock before setting parameters. (Refer to Key Lock setting below.)
RUN mode
Press
key
Press
over 3sec.
key over
3sec.
Pressure unit
setting
Press
key
Output operation
mode setting
Press
key
Output setting
Press
key
Response time
setting
Press
key
2
Press
over 1sec.
UNIT and previously set unit will flash in turn every 0.5 sec.
Press
or
key to select the unit.
(Press
key for 1 sec to save selected unit and move to next mode.)
● Negative pressure, compound pressure:
(kPa)
(kgf/cm
2
)
● Standard pressure:
MPA
(kPa)
(MPa)
and previously set output operation mode will flash in turn every 0.5 sec.
Press
or
key to select output operation mode.
(Press
key for 1 sec. to save selected output operation mode and move to next mode.)
and previously set output operation mode will flash in turn every 0.5 sec.
Press
or
key to select output type.
(Press
key for 1 sec. to save selected output type and move to next mode.)
and previously set output operation mode will flash in turn every 0.5 sec.
key to select Response time .
Press
or
(Press
key for 1 sec. to save selected Response time and move to next mode.)
Pressure Sensor
If executing zero point adjustment when external
pressure has been applied,
Please execute zero-point adjustmentagain in
state of atmospheric pressure without external
pressure.
(bar)
(psi)
(mmHg)
(bar)
(kgf/cm
2
)
(psi)
will fl ash.
₂
(inHg)
(mmH
O)
※ For using mmH
₂
O unit,
multiply display value
by 100.
※ Refer to E-14 page.
(unit: ms)
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
power
supply
(Q)
Stepping
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
E-9