Autonics FXS Series Produkthandbuch - Seite 3

Blättern Sie online oder laden Sie pdf Produkthandbuch für Zeitschaltuhr Autonics FXS Series herunter. Autonics FXS Series 5 Seiten. Din w48xh48mm, preset counter/timer
Auch für Autonics FXS Series: Handbuch (8 seiten)

Autonics FXS Series Produkthandbuch
Detach DIP Switch Cover
• Push and pull the groove of DIP switch cover with a flat
head (-) driver to the front, detaching the cover from the
case.
᜸ Caution: Turn OFF the power before detaching
᜸ Caution: When using the tools, be careful not to

DIP Switch Setting

7 6 5 4 3 2 1 5 4 3 2 1
ON
OFF
SW2
SW1
■ DIP SW1
Function
SW1
Counter
Timer
CP1, CP2, INHIBIT, RESET input logic
1
2
-
Time range
3
Input operation mode
4
Count up /
-
5
count down
• Input logic
SW1-1
Input logic
NPN (no-voltage input)
ON
PNP (voltage input)
OFF
• [Counter] Input operation mode
SW1
Count up / count down &
input operation mode
5
4
3
Up / Down - A
OFF OFF OFF
(command)
Up / Down - B
OFF OFF ON
Count
(individual)
up
Up / Down - C
OFF ON
OFF
(phase difference)
Up
OFF ON
ON
Up / Down - D
ON
OFF OFF
(command)
Up / Down - E
ON
OFF ON
Count
(individual)
down
Up / Down - F
ON
ON
OFF
(phase difference)
Down
ON
ON
ON
■ DIP SW2
Function
SW2
Counter
Timer
1
Counter / Timer
Max. counting speed
-
2, 3
Memory retention
4
Output operation mode
5, 6, 7
01)
01)  Except the indicator model.
• Counter / Timer
SW2-1
Counter / Timer
Counter
ON
Timer
OFF
• [Counter] Max. counting speed
SW2
Max. counting speed
3
2
1 cps
OFF
ON
30 cps
OFF
OFF
2 kcps
ON
OFF
5 kcps
ON
ON
the cover.
be wounded.
• Detach the cover of DIP switch and
proceed the settings. See the 'Detach DIP
Switch Cover.'
• How to change the settings:
power OFF → change settings → power
ON → press [RESET] key or input the
RESET signal (≥ 20 ms) to the external
terminal.
Defaults
ON
OFF
OFF
OFF
OFF
• [Timer] Time range
SW1
Time range
4
3
2
4-digit
5-digit
OFF OFF OFF 99.99 s
9999.9 s
999.9 s
99999 s
OFF OFF ON
OFF 9999 s
9 m 59.99 s
OFF ON
99 m 59 s
99 m 59.9 s
OFF ON
ON
OFF OFF 999.9 m
9999.9 m
ON
99 h 59 m
9 h 59 m 59 s
ON
OFF ON
OFF 999.9 h
999 h 59 m
ON
ON
9999 h
9999.9 h
ON
ON
ON
Defaults
ON
OFF
OFF
OFF
• Memory retention
SW2-4
Memory retention
×
ON
OFF
• Output operation mode
SW2
Output operation mode
7
6
5
OFF OFF OFF F
N
OFF OFF ON
OFF C
OFF ON
R
OFF ON
ON
OFF OFF K
ON
P
ON
OFF ON
OFF Q
ON
ON
S
ON
ON
ON

Input Connections

• Input: CP1, CP2 (INHIBIT), RESET
• Max. counting speed in the contact input: 1 or 30 cps setting (counter).
■ No-voltage (NPN) input
• Solid-state input
Sensor
(NPN output)
Counter / Timer
Brown
+12 V
5.4 kΩ
Black
Internal circuit
of input part
Blue
0 V
• Contact input
Counter / Timer
+12 V
5.4 kΩ
Internal circuit
of input part
0 V
■ Voltage (PNP) input
• Solid-state input
Sensor
(PNP output)
Counter / Timer
Brown
+12 V
Black
Internal circuit
of input part
10.8 kΩ
Blue
0 V
• Contact input
Counter / Timer
+12 V
Internal circuit
of input part
10.8 kΩ
0 V
Sensor
(NPN open collector output)
Counter / Timer
Brown
+12 V
5.4 kΩ
Black
Internal circuit
of input part
Blue
0 V
Sensor
(PNP open collector output)
Counter / Timer
Brown
+12 V
Black
Internal circuit
of input part
10.8 kΩ
Blue
0 V