Autonics LE7M-2 Handbuch - Seite 5
Blättern Sie online oder laden Sie pdf Handbuch für Zeitschaltuhr Autonics LE7M-2 herunter. Autonics LE7M-2 13 Seiten. W72xh72mm lcd week/year digital timers
Auch für Autonics LE7M-2: Handbuch (13 seiten), Handbuch (13 seiten), Produkthandbuch (5 seiten)
• Set range for ON/OFF time width
: 1min to 12 hour 59 min
• One record in 3 steps (ON day/ON time, OFF day/OFF
time, ON time width/OFF time width)
OFF width
ON time
● Weekly pulse mode
Output turns ON at ON time for a specified pulse width.
(pulse width: 1 to 59 sec, 1 to 60 min)
• One record in two steps (ON day/ON time, pulse width)
Pulse width
(1 to 59 sec, 1 to 60 min)
ON Time
● Yearly ON/OFF mode
Output turns ON at ON time on START date and turns OFF
at OFF time on STOP date.
• One record in three steps
(START/STOP date, ON/OFF time)
● Yearly pulse mode
Output turns ON at ON time on START date and turns
OFF at OFF time on STOP time for a specified pulse width
repeatedly. (pulse width: 1 to 59 sec, 1 to 60 min).
• One record in three steps (START/STOP date, ON time,
pulse width)
Program operation
Weekly setting 1 of Program 1
Weekly setting 2 of Program 1
Yearly setting 1 of Program 1
Program 1 mode
● ①to②: Operated by weekly setting 1 of Program 1.
● ②to③: Operated by weekly setting 2 of Program 1.
● ④to⑤: Operated by weekly setting 1 of Program 1.
● ⑤to⑥: Operated by yearly setting 1 of Program 1.
(during weekly program operation at 12:00 AM on
START date, the weekly program operation stops, and it
changes to yearly program operation mode. The yearly
program operation stops at 12:00 AM on the next day of
STOP date.)
Display and change of next mode
● The day of next mode in Program 1 or Program 2 is
displayed on the day indicator, and the time of next
mode is displayed on the lower row of screen.
Press
+
in RUN mode it is changed from
program 1 to program 2 or from program 2 to program 1.
● In ON/OFF operation mode, set ON time and OFF time
to next mode. In Pulse operation mode, set Pulse ON
time to next mode.
ON width
OFF time
①
② ③ ④
⑤ ⑥
Weekly/Yearly Timer
Power restore mode
In setting group 2-Level 2 (power restore), select auto [ AT ]
or normal [ NOR ] by
or
● Auto [ AT ] power restore mode
Output (OUT1, OUT2) operates according to program
when power turns on again after power failure.
● Normal [ NOR ] power restore mode
When power turns on again after power failure, output is
kept OFF and RET.IN flashes on the panel. When power
restore input is detected, RET.IN turns off and output
operates according to program.
• Power restore input
Input contact signal in external "Return input terminals
(⑨ to ⑩)" by switch or relay, or press
in RUN mode.
Please use reliable contacts enough to flow 0.1mA of
current at 5VDC when use switch or relay.
Season switching mode
This feature uses for setting seasonal weekly operation
mode.
To operate this mode, save starting month and date,
ending month and date of each season which displays S1,
S2, S3, S4 then set day and time of each season in weekly
program setting. It is also able to operate only in summer
and winter season. (S1: set summer season, S2: set winter
season, S3/S4: do not set)
At the season switching selection LEVEL 2 status in setting
2 group ( SEN turns ON, OFF flashes), select ON [ ON ] by
pressing
or
key and press
season switching.
Be sure that if changing season switching from OFF to ON
or, ON to OFF , the weekly program 1 (P1) and the weekly
program 2 (P2) which are set before are deleted.
● ON [ ON ] mode
Weekly program is switched automatically by season
switching.
• Period setting per season
①At the season switching selection LEVEL 2 status in
setting 2 group ( SEN flashes, the set season turns ON,
START and STOP turn ON), press
②Advance to the flashing position of season selection
among S1, S2, S3, S4 by
key.
③After set START month, date per season and press
key.
④
key is pressed after set STOP month, date per
season, it is advanced to LEVEL1 of period setting per
season. Add or adjust the period setting by
● It is disable to use when it is OFF [ OFF ].
● If season terms are overlapped, these are prioritized in
S4>S3>S2>S1 order.
key, and press
key to set.
key for 3 sec
key to complete the
key.
or
key and press
key.
N-85
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J)
Temperature
Controllers
(K)
SSRs
(L)
Power
Controllers
(M)
Counters
(N)
Timers
(O)
Digital
Panel Meters
(P)
Indicators
(Q)
Converters
(R)
Digital
Display Units
(S)
Sensor
Controllers
(T)
Switching
Mode Power
Supplies
(U)
Recorders
(V)
HMIs
(W)
Panel PC
(X)
Field Network
Devices