FLUID REFILLING SET
1. FEATURES
•
Designed for refilling ATF, gear oil and differential oil
•
Can be operated pneumatically and manually
•
Large tank (12.5L/3.3 gallon) are suitable for transmissions that require volume of ATF
•
Provided with 20 adapters for transmissions without a dipstick
•
Temperature range: -40 to 80°C
2. PRECAUTIONS
•
Tank does not have vacuum function.
•
DO NOT fill the tank with solvent or fuel.
•
DO NOT adjust pressure regulator. Incorrect pressure setting may cause danger.
•
Always read completely the instruction manual before working.
CAUTION
•
Never used the tool in the areas that it is not designed for.
•
Always wear eye protection that meets OSHA and ANSI Z87.1 standards.
•
Always wear hand gloves when working with the tool.
•
Ensure the work area has adequate lighting.
•
Keep children and unauthorized persons away from the work area.
•
Keep work area clean and tidy and free from unrelated materials.
•
DO NOT allow untrained persons to use the kit.
3. SPECIFICATIONS
1
2
3
4
4. INSTRUCTIONS
1
Drain old automatic transmission fluid (ATF) from transmission.
2
Refill new ATF into tank by opening Refiller Cap (4).
3
Choose a suitable adapter and connect to hose end.
4
Connect the hose to Hose Connector (2) on tank.
5
Connect shop air to Shop Air Connector (5).
6
Screw or hook adapter on transmission refilling hole (Fig. 1).
7
Open Air Switch (5) and open the valve on hose end.
8
Before refilling up to the specified volume of ATF, turn off the Air Switch (5).
9
Push the Square Handle (1) backward to release pressure in tank.
10
Start to pump manually to reach the specified volume of ATF.
No
Description
1
Square Handle
5
2
Hose Connector
3
Gauge
6
4
Refiller Cap
5
Shop Air Connector and Switch
7
6
Pressure Regulator
8
7
Auto Release Valve
8
Lid
www.9circleint.com
Specification / Remarks
Push backward for releasing pressure
Pressure 0-35 psi / 0-2.5 kg/cm
Open when refilling fluid
Preset at 7-28.5 psi / 0.5-2.0 kg/cm
Preset at 14.2 psi / 1 kg/cm
DO NOT open
EN
2
2
2
Fig. 1