Autool BT-660 Benutzerhandbuch - Seite 7

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Prüfgeräte Autool BT-660 herunter. Autool BT-660 9 Seiten. Battery system tester
Auch für Autool BT-660: Benutzerhandbuch (5 seiten)

Autool BT-660 Benutzerhandbuch
After the test finished, tester displays the effective ,charging ,volts,
tipple test result and charging test result.
NOTE: If no increase rev detected, it shall be the fault of generator
regulator or connection with battery failed. Tester will try 3 times to
further detect, if still failed, it will skip the increase rev detect and
the test result displays "No Volt Output".
Check the connection between generator and battery, then retest.
Charging Test Result:
1.Charging Volt: Normal. The generator output normal, no problem
detected.
2.Charging Volt: Low. Check drive belt of the generator whether
slip or running off.Check the connection between generator and
battery is normal or not. If both of the drive belt and the connection
are in good condition, follow the manufacturer's suggestion to
eliminate generator fault.
3.Charging Volt: Hight. Since most of the vehicle generators are
using internal regulator, the generator assembly has to be