Dynaset 90 Installationshandbuch - Seite 5
Blättern Sie online oder laden Sie pdf Installationshandbuch für Water Pump Dynaset 90 herunter. Dynaset 90 16 Seiten. Hydraulic variable displacement pump
3.
TECHNICAL SPECIFICATIONS
OUTPUT
Geometrical displacement per revolution V
Flow at max RPM and V
Flow at n=1500 RPM and V
Drive power at Δp=250 bar at 2000 RPM
Required drive torque at V
HYDRAULIC CONNECTIONS
HYDRAULIC FLUID REQUIREMENTS
Filter ratio, recommendation
OVERALL DIMENSIONS
Gallons are U.S. liquid gallons
*Different flange size options available depending on the required flow rate. 38mm(1 1/2"), 42 mm,
50mm(2"), 64mm(2 1/2"), 76mm(3").
** Without the Suction flange.
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | [email protected] | www.dynaset.com
HYDRAULIC VARIABLE DISPLACEMENT PUMP
max
g
Speed
n
max
q
g
V max
max q
g
VE max
P
max
T
Drive torque max.
max
T
max, Δp=100bar
g
Pressure Δp nom
.
Pressure Δp max.
Pressure line
P
Suction line
S
LS - line
LS
Dr
Drain line
Viscosity
Temperature
Cleanliness level
Flange
Length**
Width
Height
Weight approx.
INSTALLATION GUIDE
60
cm
/rev
60
3
(in
/rev)
(3.66)
(5.49)
3
RPM
500 - 2500 500 - 2300 500 - 2200
l/min
150
(gpm)
(39.6)
(54.6)
l/min
90
(gpm)
(23.7)
(35.6)
kW
53
Nm
430
(lb ft)
(310)
Nm
100
(lb ft)
(73)
bar
350
(psi)
(5100)
(5100)
bar
400
(psi)
(5800)
(5800)
G 3/4"
*
G 1/4"
G 1/4"
G 3/4"
G 3/4"
cSt
10-1000 / optimum 25-50
°C(°F)
max. 70 (158)
μm
ISO 4406
21/18/15 ... 19/17/13
DIN ISO
DIN ISO
7653
253,5
277.5
mm (in)
(9.94)
(10.93)
115
mm (in)
(4.53)
(4.72)
193,75
193,75
mm (in)
(7.63)
(7.63)
kg (lbs)
24 (53)
27(60)
90
110
90
110
(6.71)
207
242
(63.8)
135
165
(43.5)
79,5
97,2
530
900
(390)
(590)
151
184
(111)
(135)
350
350
(5100)
400
400
(5800)
G 1"
G 1"
*
*
G 1/4"
G 3/4"
25≥
DIN ISO
7653
7653
279,5
(13.07)
120
122
(4.80)
255,10
(10.04)
30 (66)
5