Dynatech iTronix X-C 6250 Technisches Bulletin
Blättern Sie online oder laden Sie pdf Technisches Bulletin für Laptop Dynatech iTronix X-C 6250 herunter. Dynatech iTronix X-C 6250 2 Seiten. Cradle contact cable assembly replacement procedure
X-C 6250/X-C 6250 Pro Computers
Cradle Contact Cable Assembly Replacement Procedure
Note: Considerations to prevent ESD damage to the cradle PCB components should be observed. Avoid contact with
the cradle PCB and components.
Tools required: #1 Philips screw driver
Procedure:
1. Ensure that power is disconnected from the cradle.
2. Remove the 14 screws that attach the cradle L base to the cradle case.
a) Remove the 6 screws from the back of the cradle.
b) Position the cradle so the bottom is face up and remove the 8 screws on the bottom.
c) Slide the L base toward the back of the cradle to allow the cradle PCB to clear the cradle case
3. Lift the L Base up slightly from the front (approximately 45 degrees) to allow access to the cable connection on the cradle
PCB.
4. Grasp the top portion of the white connector (Cable to PCB [Male]) and press the locking tab to disconnect from the PCB.
Locking Tab
801 South Stevens • P.O. Box 179 • Spokane, WA 99210 • 509.624.6600 • 800.441.1309
BellSouth Units Only
Cable to PCB
Connector(Male)
Cable to PCB
Connector(Female)
Technical
Bulletin
97-0051-001
09/99