SAFETY PRACTICES & PRECAUTIONS
WARNING:
ALL WALL AND FLOOR OPENINGS WHERE THE Downdrdt
IS INSTALLED MUST
BE SEALED.
ConsuHt the cooktop
or range installation
instructions
given by the manufacturer
before making any
cutouts.
MOBHLE HOME INSTALLATION - The installation
of this Downdraft
must conform
to the
Manufactured
Home Construction
and Safety Standards, TitHe 24 CFR, Part 3280 (formerly
FederaH
Standard for Mobile Home Construction
and Safety, TitHe 24, HUD, Part 280).Three wire power suppHy
must be used and the appHhnce wiring
must be revised. See Electrical Requirements.
[] Venting system MUST terminate
outside the home.
[] DO NOT terminate
the ductwork
in an attic or other enclosed space.
[] DO NOT use 4" hundry4ype
wall caps.
[]
Flexible-type
ductwork
is not recommended.
[] DO NOT obstruct
the flow of combustion
and ventilation
air.
[] Failure to follow venting
requirements
may result in a fire.
[] Electrical ground is required on this Downdraft
system.
[] If cold water pipe is interrupted
by plastic, non-metallic
gaskets or other materials, DO NOT use
for grounding.
[] DO NOT ground
to a gas pipe.
[] DO NOT have a fuse in the neutral or grounding
circuit.
A fuse in the neutral
or grounding
circuit could result in electrical
shock.
[] Check with a qualified
electrician
if you are in doubt as to whether
the downdraft
is properly
grounded.
[] Failure to follow electrical
requirements
may result in a fire.
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLO WING:
Use this unit only in the manner intended
by the manufacturer.
If you have
any questions,
contact
the manufacturer.
Before servicing
or cleaning
unit,
switch power offat
service panel and lock the service disconnecting
means
to prevent
power from being switched
on accidentally.
When the service
disconnecting
means cannot be locked, securely fasten a prominent
warning
device, such as a tag, to the service panel.
Installation
Work And Electrical
Wiring
Must
Be Done
By Qualified
Person(s)
In Accordance
With
All
Applicable
Codes
And
Standards,
Including
Fire-Rated
Construction.
Sufficient
air is needed for proper combustion
and exhausting
of gases from
fuel burning equipment
through
the flue (chimney) to prevent backdrafting.
Follow
the
heating
equipment
manufacturer's
guideline
and
safety
standards
such
as those
published
by the
National
Fire Protection
Association
(NFPA), and the American
Society for Heating, Refrigeration
and
Air Conditioning
Engineers (ASHRAE), and the local code authorities.
When
cutting
or drilling
into wall or ceiling, do not damage electrical
wiring
and
other hidden utilities.
Ducted fans must always be vented to the outdoors.