CopperOptics 150-1365-51 Handbuch - Seite 5

Blättern Sie online oder laden Sie pdf Handbuch für Fernsteuerung CopperOptics 150-1365-51 herunter. CopperOptics 150-1365-51 20 Seiten. Remote terminal enclosure

CopperOptics 150-1365-51 Handbuch
Revision 01
System
Subscriber Terminations
Subscriber Protection
HDSL Terminations

2. Specifications

Environmental
Operating Temperature ...............................-40° F to +150° F (-40° C to +65° C)
Operating Humidity ....................................5% to 95% (non-condensing)
Operating Elevation ....................................-200 feet to 13,000 feet (-60 m to 4,000 m)
Physical
Dimensions
Height: .................................................19.25 in. (48.9 cm)
Width: ..................................................16.50 in. (41.9 cm)
Depth: ..................................................06.44 in. (16.4 cm)
Weight:
List 5: ...............................................24.4 lb (11.1 kg)
List 5A: ............................................35.7 lb (16.2 kg)
B. FUNCTIONAL DESCRIPTION

3. Operational Capabilities

3.1
The FRE-765 List 5x RT Enclosure requires the following plug-in units:
one RT Line Unit which is line powered via the HDSL pairs that connect the RT to the PG-Flex
COT installed in a COT Shelf.
one Channel Unit, minimum, with a maximum installation of four Channel Units, supporting up
to 32 channels.
PG-Flex FRE-765
June 2, 1997
Table 1. Features of FRE-765 5x RT Enclosures
16 Channel
32 Channel
25-pr Amphenol (male)
AMP Insulation Displacement
5 pin sockets (short housing)
AMP Insulation Displacement
PairGain Engineering - Plant Series
Section 363-765-105
List 5
List 5A
(Figure 1)
(Figure 2)
l
l
l
l
l
l
l
l
l
Page 3