Galls K9 Partner Gebrauchsanweisung - Seite 19

Blättern Sie online oder laden Sie pdf Gebrauchsanweisung für Türöffnungssystem Galls K9 Partner herunter. Galls K9 Partner 20 Seiten. Power door opener

K9 Partner Power Door Opener System with PowerTouch Remote Control
Trouble Shooting Guide - K9 Partner door Opener
Symptom
8.0 Actuator will not
pull the latch open
Symptom
9.0 Gas strut will not
push the door open
Possible Cause
8.1 Actuator does not
have enough force to
pull latch
Possible Cause
9.1 Angle of strut is
correct
9.2 Gas strut was
installed with hydraulic
grease at top of angle
Corrective Action
8.1a Install spring in parallel with actuator pull to
enhance it.
8.1b Shorten length of actuator travel distance to
a maximum of 3/4". Any distance over 3/4"
reduces pull force by one half.
8.1c Install a pair of lever struts to improve the
mechanical advantage of the pull and also to
increase the travel distance of the pull.
Corrective Action
9.1 Change mounting location and angle of gas
strut to push the door open.
9.2 Strut hydraulic gas / grease has drained from
cylinder. This is considered customer damage and
is NOT covered under warranty.
Manual C840.N2
Page -19-