4. Technical specification

4.6. Technical specification of the SGW(S) Vulcan - free-standing

Specification
Storage capacity
*
Maximum working temperature
Maximum working pressure
Heat exchanger surface
Heat exchanger capacity
Demand tor central heating water
Efficiency (70/10/45°C)
Heating power
Dimensions
A
B
C
D
E
L - height
Tank dimensions (without insulation)
Tank dimensions (with insulation)
Soft polyurethane foam insulation
External housing
Connections
Cold water / hot water
Circulation
Heating water circuit (supply/return)
E-coupler (heater)
Sensor cover
Thermometer
Water drain
Magnesium anode
Weight (empty)
According to the (UE) 812/2013, 814/2013.
*
10
Installation and Operating Manual - SGW(S) Vulcan
unit
SGW(S) 100
l
101
°C
bar
m
2
l
m
/h
3
l/h
kW
mm
mm
mm
mm
mm
mm
990
Ø
mm
mm
-
R
R
R
R
R
Gw
Gw
-
kg
57
SGW(S) 120
SGW(S) 140
113
127
100
6
1,2
5,2
2,5
700
29
140
60
40
100
120
1090
1240
400
455 x 455
25
metal jacket
3/4"
3/4"
3/4"
5/4"
3/8"
3,8"
3/4"
plug 5/4"
62
67
© All rights reserved - Galmet Sp. z o.o. Sp. K.
SGW(S) 200
194
1,6
11,2
2,6
950
39
190
1130
550
650 x 650
50
1"
1"
1"
6/4"
1/2"
1"
85