READ COMPLETE SAFETY INSTRUCTIONS AND INSTALLATION TEMPLATE BEFORE STARTING
This product must be installed by a qualified heating and air conditioning contractor. Failure to do so could result in serious injury from electrical shock.
WARNING
ELECTRICAL SHOCK HAZARD.
1.
Disconnect electrical power to the
furnace and install lock-out tag
before starting installation. Failure to
do so could result in serious injury
from electrical shock.
SHARP EDGES HAZARD.
2.
Sharp
edges may cause serious injury from
cuts. Use care when making plenum
openings and handling ductwork.
RISK OF SCALDING.
3.
Water
temperature over 125°F can cause
severe burns and scald instantly.
Shut off the hot water supply before
disconnecting or tapping into any hot
water supply line.
HumidiTrac
Automatic Humidifier Control
For detailed Automatic Humidifier Control
installation and wiring instructions,
see Form IM-AHC-03 included with Control.
DIAGRAM C
FOR HUMIDIFIER OPERATION WITH HUMIDITY SENSING
THERMOSTAT
WARNING: DO NOT CONNECT FURNACE HUM TERMINAL
DIRECTLY TO HUMIDITY SENSING THERMOSTAT HUM TERMINAL
24 VAC
SOLENOID VALVE
LEADS
90-1117
HUMIDIFIER
(HUM)
TERMINAL
INDOOR
EQUIPMENT
(R) 24 VAC
HOT TERMINAL
© 2018 CAC/BDP
7310 West Morris St., Indianapolis, IN 46231
ATTENTION INSTALLER:
This product must be installed in compliance with all local, state and federal codes.
SBP SMALL BYPASS HUMIDIFIER
RISK OF PROPERTY AND EQUIPMENT DAMAGE.
1. Do not install humidifier where freezing temperatures
could occur. The water line could freeze and crack
causing water damage to the home.
2. Do not install humidifier or bypass connection on the
furnace cabinet.
3. Do not install humidifier or bypass connection on a
plenum face where the blanked off ends of the cooling
coil will restrict air movement through the humidifier.
4. Do not set humidity level above recommended or to
recommended level if condensation exists on inside
windows of any unheated space, as condensation
damage may result. Excess humidity can cause
moisture accumulation which can allow the possibility
for mold growth in the home.

WIRING DIAGRAMS

DIAGRAM A
FOR OPERATION DURING "HEAT CALL" ONLY
HUMIDIFIER
24 VAC TERMINALS
ON FURNACE
DIAGRAM D
ZONING HOOK-UP
WITH EQUIPMENT CONTROLLER
HUMIDIFIER
HUMIDITY SENSING
90-1118
THERMOSTAT
TEMPLATE MUST BE LEVEL
CAUTION
5. Do not connect humidifier transformer to
blower motor wiring. Premature component
failure may result.
6. When installing Humidifier Control on downflow
furnace, ensure blower continues to run
after a heat call is satisfied to eliminate high
temperatures from damaging the Control.
7. Do not install humidifier where water pressure
exceeds 125 psi, since damage to the
humidifier may result. Follow codes in effect
concerning pressure reduction.
8. Do not install humidifier on systems with
greater than 0.4 in. wg pressure differential
between supply and return plenums.
FOR OPERATION WHEN BLOWER IS ENERGIZED
24 VAC
SOLENOID VALVE
LEADS
HUMIDIFIER
90-1115
120 VAC "EAC"
TERMINALS
120 VAC
ON FURNACE
MANUAL
TRANSFORMER
HUMIDIFIER CONTROL
(FIELD SUPPLIED)
NEW COMMUNICATING CONTROL HOOK-UP
WITH ALL INDOOR EQUIPMENT
EQUIPMENT
CONTROLLER
24 VAC
SOLENOID
VALVE
LEADS
HUMIDIFIER
INDOOR
UNIT
90-1119
SPECIFICATIONS
HUMIDIFIER DIMENSIONS
Width
Height
INSTALLATION OPTIONS
RETURN
The humidifier can be installed on
DIAGRAM B
either the supply or return plenum
RETURN
of a forced air handling system and
is easily reversible for installation
NOTE: CONNECT SOLENOID
with right hand or left hand bypass
VALVE TO HOT WATER IF
HUMIDIFIER WILL BE
duct connections. The humidifier
OPERATED INDEPENDENT
dimensions and serviceability must
OF HEATING CALLS.
be considered when selecting the
best location for the humidifier.
24 VAC
SOLENOID VALVE
LEADS
90-1116
24 VAC
MANUAL
HUMIDIFIER CONTROL
RETURN
DIAGRAM E
RETURN
INDOOR
UNIT
24 VAC
SOLENOID
VALVE
LEADS
15
"
5
(including solenoid valve):
8
13"
(including drain spud):
Depth
10
"
:
1
4
BYPASS DUCT OPENING
6" diameter
PLENUM OPENING
9
"W x 9
"H
1
1
2
2
WATER FEED RATE
3 gph
ELECTRICAL DATA
24 VAC-60 Hz, 0.5 AMP
SUPPLY
SUPPLY
Upflow
SUPPLY
SUPPLY
Horizontal
RETURN
RETURN
SUPPLY
SUPPLY
90-1079