Event Notifications and Reports

The CS1030 Wall Outlet has the following event notifications:
Outlet Socket Notifications:
Outlet ON (energized) – The outlet is powered on (default enabled)
Outlet OFF (de-energized) – The outlet is powered off (default enabled)
Additionally, statistics can be enabled to report aggregate outlet socket event activity:
ON Counter (how many times socket has been switched on)
OFF Counter
Current ON or OFF time duration (current state of the switch)
Min/Max ON Duration
Min/Max OFF Duration
This device includes temperature measurement capabilities. If your application supports the
Temperature API, the following events & statistics are available:
Temperature Event Notifications:
Temperature value greater than or less than specified value
Temperature relative change (positive or negative or both) exceed specified threshold
Temperature Statistics:
Min Temperature
Max Temperature
Average Temperature
Temperature Variance (take square root to get standard deviation)
Samples takes in last period
All Statistics are stored in non-volatile memory and will persist through a power outage. Both the
statistic reporting and alarms can be configured remotely by sending downlink messages.
The device has a periodic Heartbeat status message that is sent to maintain LoRaWAN network
connectivity. The default period for this message is 60 minutes and may be configured between
two (2) minutes minimum and 48 hours maximum.