User
Interface
The CS1030 user interface is shown in the figure below.
Figure 3 – Performing Network or Factory Reset on the Wall Outlet
The device provides one switched outlet and one always-on outlet, a 2.4A (5V) USB charger, an
LED Indicator, and a push button.

Push Button

The Status LED on the front of the CS-1030 indicates the following status:
Action
One (1) quick press
Two (2) quick presses
Press and hold > 10 seconds
Press and hold > 25 seconds
CS1030 Long Range Wall Receptacle Outlet – User Guide
Description
Default toggles the switched outlet on/off.
Default turns on switched outlet for three minutes
Network Reset
Press and hold the SET button for 10 seconds, but less than 25,
then release. The device will reset all LoRaWAN Settings, which
does not affect device operation or configuration.
Factory Reset
Press and hold the SET button for > 25 seconds, then release.
The device will reset all parameters to factory defaults.
Following reboot, a Factory Reset event uplink (confirmed) will
be sent upon rejoining the LoRaWAN network.