Agrox RTU5015 Benutzerhandbuch - Seite 8
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Controller Agrox RTU5015 herunter. Agrox RTU5015 12 Seiten. Gsm gate opener remote switch
6.7 Inquiry Alarm Setting
pwd#AL?
Reply:
Alarm Inputs Disabled or
Tips:
Alarm Inputs Disabled means disable the digital inputs, Alarm Inputs Enabled means Enable digital
inputs.
6.8 Setup allow all calling in numbers can access it
pwd#AA#
Tips:
This command allows anybody calling the SIM number to access it.
Warning! With the above command you allow free access to anybody calling!
6.9 Setup only authorized number can access it (Default)
pwd#AU#
Tips:
With the above command you allow only people that are in the authorized number list can
access the RTU5015. This is the standard and recommended option.
Inquiry this setting
pwd#AC?#
Relpy:
Allow all numbers can access it
6.10 Setup the relay close time
pwd#GOTTime#
Tips:
The time should be in 0~9.5seconds.
This command is useful in case you need to keep the relay closed (or button pressed) longer. The default
time is 0.5seconds (500 ms). You can change it with the GOT command. The relay closed time is twice as
the number you set, e.g.: if you set pwd#GOT19#, means the relay closed 19/2=9.5Seconds.
To check the value, you can use the command
If you want to let the relay always closed until you call it next time, then you can set the time as 00, the
format is pwd#GOT00#, the relay will be always closed until next time call in. in this case, only the 1
3rd authorized number can access it. The other authorized numbers can not access the unit. This is very
useful for remote switch on or switch off the electricity appliance or equipment or device for a long time.
6.11 Modify the digital input type
pwd#KEYNC#
Modify the digital input type as NC; if the sensor you used with this unit is NC, then you should set the unit
as NC type.
Tips:
when you set the digital inputs as NC, if you don't use the input, please connect the digital inputs by
a wire to short it. Otherwise, it will alarm. E.g.: if you only use the input 2, then you should use a wire to
Alarm Inputs Enabled.
or
Allow User Number can access it
pwd#GOT?
Page 8 of 8 Ver 1.3
, the unit will reply the current value.
File No.:RTU501513
only.
st
, 2
nd
,