Galvin Engineering CliniLever TCWMJ80HC Installations-Manuale - Seite 3

Blättern Sie online oder laden Sie pdf Installations-Manuale für Sanitärprodukt Galvin Engineering CliniLever TCWMJ80HC herunter. Galvin Engineering CliniLever TCWMJ80HC 4 Seiten. Cp-bs hospital washing machine tap

Galvin Engineering CliniLever TCWMJ80HC Installations-Manuale
Product Installation Guidelines
3. Fit water temperature indicator
Once lever handle is secure, fit the water
temperature indicator.
Ensure the set is installed with hot and cold
in the correct location.
TROUBLESHOOTING
PROBLEM
Taps are dripping water
Water is leaking from spindle
Water is not flowing from tap
Spindle is difficult to turn
(jumper valve)
Handle is loose
© Galvin Engineering Pty Ltd
4. Testing
CAUSE
Jumper valves are worn or damaged
Ceramic discs are worn or damaged
Tap seat is damaged
O-ring on jumper valve spindle is
damaged or worn
Water is turned off
Aerator or flow regulator is blocked by
debris
Build up of scale on spindle, spindle
worn or o-ring has been damaged
Screw has come loose
Once temperature indicator is fitted, check the
operation of the unit, and inspect for any
leaks.
RECTIFICATION
Replace jumper valve
Remove and inspect SBA.
Remove debris and/or replace
SBA if damaged.
Refurbish tap seat using a
reseating tool.
Replace o-ring
Turn water on
Remove aerator and/or flow
regulator from tap and remove
debris. Install an inline strainer.
Remove jumper valve, clean and
regrease. Replace o-ring.
Complete SBA may need to be
replaced.
Tighten handle screw
Document No.: 001.00.10.17
Version 1, 4 November 2022, Page 3 of 4