7
Check the door frame is vertical and is centrally positioned between the wall channels.
From inside the enclosure, in the positions shown, drill through the wall channels into the fixed panels using a 3mm drill bit,
do not drill too deep! Fix using 6 x 10mm screws and screw caps.
8
PN40260
PN4745
Fit 'flipper seals' (PN40260) onto the edge of the fixed
panels. Ensure the flipper seal 'flaps' are on the
inside.
Note: Wetting the glass with water will help fit the seals.
From inside the enclosure, tighten all 4 fixed panel
bracket grub screws onto the glass using the allen
key - do not overtighten. Fit the cover caps (PN4745)
into the holes.
From inside
Inside
9
PN80564
PN
40259
Outside
face of
door
Door
handle
hole
Push fit 'flipper seals' (PN40259) onto the back edge of the doors.
Ensure the flipper seal 'flaps' are on the outside of the doors.
Push fit 'magnetic seals' (PN80564) onto the closing edge of the
doors (the same side as door handle hole).
Note: Ensure the magnetic seals are positioned as shown.
Note: Wetting the glass with water will help fit the seals.
ø 3
mm
10mm
PN40259
PN80564
Outside
face of
door
PN80564
Door
handle
hole
5