manifolds. If the manifolds do not line up from one
appliance to another, re-check the level and correct so
that ALL appliances are on the same plane.
CAUTION
All gas manifolds must align correctly to each
other. Failure to provide proper alignment can
damage gas manifolds, pilot and gas valves.
ADJUSTABLE LEG INSTALLATION
Raise the appliance above the floor. In the bottom
plate of the appliance, locate the 5/8" nuts that are
welded into the bottom plate. Thread each of the
legs into these nuts tightly. Check that leg height
adjustment operates freely.
OPTIONAL CASTER INSTALLATION
Raise the appliance above floor. If legs are installed,
remove them. Install casters by threading caster
bolts tightly into nuts that are welded into the bottom
plate of the appliance. (locking caster in front only).
Figure 2: Caster Installation
CAUTION
Floors more than 1/4" out of level over the span
of a single appliance should NOT use casters
as they cannot be leveled. (5/8" washers not
exceeding 1/4" total thickness may be added to
caster stem to level unit).
NOTE: When the appliance is to be installed with
casters, gas connection must be made with
approved connectors for movable gas appliances
(ANSIZ21.69 and addendum Z21.69189) with a
quick-disconnect device approved for gas fuel.
(ANSIZ21.41) In addition, a secure method of
limiting the movement of the appliance must be
Jade Range LLC – A Middleby Company
provided to protect the connector, gas line or any
associated gas piping from excess tension or
being pulled from its connection.
This restraining device must always be in place when
the appliance is in use. If it is to be removed for cleaning
purposes or to service the appliance, it must be re-
installed before the appliance is put back into service.
Per ANSI regulations Z-21.69 (connectors), Z-83.11
(commercial gas ranges), Z-21.41 (quick-disconnect
devices), with latest revisions.
RESTRAINING DEVICE INSTALLATION
Welded nut
This is a separate cable and should be less than 6"
away from the gas connector in a parallel orientation.
1. Adjust cable clamps (1) so that cable length is
2. Secure eyelet plate to structurally sound
3. Attach the scissor hook to the staple and
4. Attach the spring hook to the gas appliance.
5. ** Check to make certain that the overall length
EYELET CABLE AND ALL CONNECTIONS TO
WALL AND APPLIANCE MUST BE STRONG
AND SECURE ENOUGH TO PREVENT
APPLIANCE MOVEMENT FROM PULLING ON
GAS FITTING IN ANY WAY WHEN THE
APPLIANCE IS MOVED.
Titan
TM
Model Series JTRH & JTRHE
CAUTION
Figure 3: Restraining Device
(Must be installed when casters are used)
3" to 6" shorter than the length of the gas
connector including fittings.
attachment such as wall stud or other solid
attachment point.
secure with cotter pin.
of the restraining device is 3" to 6" shorter than
the overall length of the gas connector.
WARNING
Series Heavy Duty Range