1
Verify Hand and Bevel of door. Illustrations shown are as viewed from the outside
or secure side of opening.
Left Hand
Hinges Left.
Open Inward.
"LH"
2
Prep door according to supplied Corbin Russwin Inc. door marker.
3
Install latch bolt using
two # 8x3/4" screws.
4
Install Strike Plate using two # 8-32x3/4" screws.
Screws
#8-32x3/4"
4) Installation Instructions
Left Hand
Reverse Bevel
Hinges Left.
Open Outward
"LHR"
7/8"
C of 1-1/2 Dia.
L
1-1/2
Centerline of
latch front
and strike
Conduit (optional) is available
to provide weather protection
for exterior applications.
Install conduit half with
recessed panel ìNot For Use
On Fire Doorî visible from
outside of door.
Right Hand
Hinges Right.
Open Inward.
"RH"
Hole for ribbon cable
1/8" Dia. holes
(2) required
Fire Stop Plate required
for fire rated doors
Slot
Outside
Attach Fire Stop Plate
of Door
Using self tapping screws
#8-32x1/2" long for wood &
metal doors
Latch Bolt
door prep
Pre-drilled
And/or tapped
Holes 2 places
4
3
Right Hand
Reverse Bevel
Hinges Right.
Open Outward
"RHR"
Hole for
ribbon
Cable
Outside
of Door
Lockbody
hole
Non Fire Rated Doors