Dea SWINGER Betriebsanleitung - Seite 4

Blättern Sie online oder laden Sie pdf Betriebsanleitung für Toröffner Dea SWINGER herunter. Dea SWINGER 20 Seiten. Electro-mechanical operator for swing gates
Auch für Dea SWINGER: Betriebsanleitung und Warnhinweise (13 seiten)

Dea SWINGER Betriebsanleitung

2 PRODUCT DESCRIPTION

Models and contents of the package
GEKO is an operator for the automation of swing gates and doors with door medium and small size. It is essentially made up of:
- an operator;
- a programmable control panel (adjustable strength, speed, operators stroke, etc..) with built-in 433.92 MHz radio receiver;
Inspect the "Contents of the package" (Pic. 1) comparing it with your product, for useful reference during assembly.
Transport
GEKO is always delivered packed in boxes that provide adequate protection to the product, however, pay attention to all information
that may be provided on the same box for storage and handling.

3 TECHNICAL DATA

Power supply (V)
Rated power transformer (VA)
Fuse F2 (A) (transformer)
Batteries
Fuse F1 (A) (batteries input)
24V operators outputs
Auxiliaries power supply output
"Warning" output
Electric lock output
Flashing light output
Receiver frequency
Transmitters type of coding
Max remote controllers managed

4 INSTALLATION AND ASSEMBLY

4.1 For a satisfactory installation of the product is important to:
• Verify that the gate complies with the legal requirements and then define the complete project of the installation;
• Verify that the gate is well balanced and that it has no points of friction in opening and closing;
• Identify an area that allows a smooth and safe manual operation of the operator;
• Verify that the operator bulk is compatible with the area chosen for the fitting (Pic. 2);
• Ensure that the space for the rotation of the arm is sufficient (Pic. 3).
• Use the length/weight graphic and the provided installations dimensions (Pic. 4) evaluating whether you prefer a 90° or a 120°
opening.
4.2 Once you have defined and satisfied these requirements, proceed with the assembly:
• fix the operator fixing plate to the pillar by using screws and plugs suitable to the type of surface and material (Pic. 5);
• mount the straight arm by using the supplied screw and washer (Pic. 6);
• insert the operator inside the wall connection plate and fix it with the provided screws and nuts (Pic. 7);
• Mount the swing fixing hinge and the curved arm to the straight arm by using the provided pins and seeger rings (Pic. 8);
• weld the hinge to the gate or fix it with screws suitable to the type of material;
4.3 How to unlock the operator
WARNING Disconnect the power supply from the control panel before releasing the operator. In case you cannot turn the power off, you
will necessarily have to re-lock the motor in the position in which it was unlocked.
Lift the cover window (Pic. 9a) and, after having inserted the unlocking key, rotate clockwise until it stops (Fig. 9b).
18
CONTROL BOARD
230 V ~ ±10% (50/60 Hz)
120 VA (230/22V)
2A
2x 12V 1,3A
15A
2x 5A
+24 V
max 200mA
+24 V
max 15 W
24V
max 5W or max 1
art. 110
24 V
max 15W
433,92 MHz
HCS fix-code - HCS rolling
code - Dip-switch
100
GEKO
Motor power supply (V)
Capacity (W)
Max torque (Nm)
Duty cycle (cycles/hour)
Maximum n° of operations in 24 hour
Operating temperature range (°C)
Opening time 90°(s)
Product weight with package (kg)
Protection degree
OPERATOR
24 V
80 W
180 Nm
20
60
-20÷50
16
12 Kg
IP44