Maipu SM3100-28TC-AC Handbuch installieren - Seite 12

Blättern Sie online oder laden Sie pdf Handbuch installieren für Netzwerk-Router Maipu SM3100-28TC-AC herunter. Maipu SM3100-28TC-AC 19 Seiten. Mypower s3100 series

Maipu SM3100-28TC-AC Handbuch installieren
S3100 Install Manual (For SM3100-28TC-AC and SM3100-52TC-AC) V4

Device Installation

Installation Notice

To ensure your security and the normal operation of
switch, please carefully read the following instructions and notices while
installing and using MyPower S3100 intelligent stackable secure Ethernet
access switch.

Installation Environment

A clean environment is necessary for normal operation of the switch.
No dust is allowed, or, the switch may be damaged by electrostatic
adherence.
The switch requires a non-condensing environment with a temperature
between 0 to 50 °C and a humidity between 10% to 90%,
The switch must be kept in a dry and cool place with sufficient space
around it for air circulation.
The switch requires a power input ranging from 100 to 240 VAC (50 ~
60Hz).
Make sure that the switch is safely grounded, in order to avoid
electrostatic damage to the device and potential dangers to people.
Avoid direct sunlight, and keep the switch away from heat sources and
strong electromagnetic interference sources.
The switch must be stably mounted to a standard 19'' rack or placed
on a desktop.
D u s t a n d P a r t i c l e s
Dust is harmful to the safe operation of the switch, which may lead to poor
contact of metal connectors or contacts caused by electrostatic adherence,
especially under low relative humidity. Such electrostatic adherence may
reduce the product lifespan and increase the chance of operation failures.
The recommended values of dust content and particle diameter of the
switch's working environment are listed below:
Maipu Confidential & Proprietary Information
.0
MyPower S3100
Page 12 of 19
series