Jafar 2511 Handbuch für Betrieb und Wartung - Seite 7

Blättern Sie online oder laden Sie pdf Handbuch für Betrieb und Wartung für Kontrolleinheit Jafar 2511 herunter. Jafar 2511 9 Seiten. Gate valves with soft seals and opening indicator

2.7 MARKINGS

The gate valve marking meets the following standards: EN-19; EN-1074-1.
The valve bodies feature markings on the front and back walls of the body chamber. The marking
contains the following data:
The location on the valve specified in the documentation features the nameplate which contains the
following data:
3 PROTECTION, STORAGE & TRANSPORT

3.1 PROTECTIVE COATINGS

All inner and outer cast-iron surfaces are protected with electro-deposited epoxy coat. The coat has been
approved for contact with foodstuffs.
The anti-corrosion coating layer minimum thickness is 250µm.
The screws connecting the body and the cover are manufactured as stainless, grade OH18N9 or Fe/Zn5
(galvanised steel).

3.2 PACKAGING

The gate valves are packed on EURO pallets (1200x800) and protected with heat-shrunk film.

3.3 STORAGE

Store the gate valves in sheltered rooms.
- valve type (defined by the product reference standard number)
- nominal diameter
- nominal pressure
- body material type
- manufacturer trademark
- manufacturer's company name and logo
- serial number
- sealing temperature rating
- construction mark "B" and/or mark "CE" (as applicable)
- product type.
OPERATION AND MAINTENANCE MANUAL
12-2016
7