Dean Forge Dartmoor W5E Betriebsanleitung - Seite 10

Blättern Sie online oder laden Sie pdf Betriebsanleitung für Herd Dean Forge Dartmoor W5E herunter. Dean Forge Dartmoor W5E 18 Seiten.

Dean Forge Dartmoor W5E Betriebsanleitung
Appliance
Fuel
Total Efficiency
Nominal heat output
Mean CO emission (at 13 % O
Mean flue gas temperature
Flue gas mass flow
Mean C
H
(at 13 % O
n
m
Mean NOx (at 13 % O
DIN Plus dust (at 13 % O
Appliance weight
Pre – Lighting Check and Commissioning
Check all Building Regulations have been adhered to.
The baffle plates are in the right position.
A smoke test has been done to check the chimney is clear.
Take a flue draught reading and make sure it meets the requirements for the stove.
Data Plate
All stoves are numbered and performance marked on a data plate which is found on a swinging arm
located in the middle front at the base of the stove.

Air Vent

Under part J of building regulations an air vent of the appropriate size must be fitted for all stoves with
a kw rating of over 5kw.
In very air tight properties designed with air permeability less than or equal to 5.0 m3/ (h.m2) per
hour, an air vent will need to be fitted for all kilowatts.
When fitting air vents any other appliance fitted within the room must be taken into account.
Please Note: Extractor fans when operating in the same room or space as the appliance may cause
problems. Extra air venting must be in place to counteract this affect.
Air vent inlet grills must not be inadvertently blocked.
Air vents must not be fitted in positions where they can be inadvertently covered up.
st
As from the 1
October 2010 a compliant Carbon Monoxide Alarm must be fitted
with the door open can cause excess smoke. The appliance must not be operated with the
Operation
appliance door left open except as directed in the instructions.
Page 10 of 18
Stove Performance
%
kW
)
%
2
ºC
g/s
3
)
Nmg/m
2
3
)
Nmg/m
2
3
)
Nmg/m
2
(MSF – Manufactured smokeless fuel)
Dartmoor 5 Eco
Foxworthy Eco
Dartmoor Baker 5 Eco
Wood
MSF
82.1
80.7
5.0
5..0
0.08
0.12
250
269
4.0
3.9
108
55
106
97
24
26
Dartmoor W5
Huccaby
Dartmoor W5 Baker Eco
Wood
MSF
83.1
79.7
5.0
5.0
0.11
0.08
249
261
3.8
3.4
92
21
96
110
10
18