Majestic 36MCUFD SERIES Installations- und Betriebsanleitung - Seite 8
Blättern Sie online oder laden Sie pdf Installations- und Betriebsanleitung für Innenkamin Majestic 36MCUFD SERIES herunter. Majestic 36MCUFD SERIES 20 Seiten. Unvented vent-free fireboxes
CLEARANCES
and
Ensure that minimum clearances shown in Figures 4 through 7 are
maintained. Left and right clearances are determined when facing the
front of the firebox.
Follow these instructions carefully to ensure safe installation. Failure
to follow these requirements may create a fire hazard.
Sidewall clearances: The clearance from the inside of the
1.
appliance to any combustible wall should not be less than 6".
See Figure 4.
Ceiling clearance: The ceiling must be at least 42" from the
2.
top of the firebox opening. See Figure 4.
3. Back wall clearance: The appliance may be placed against a
combustible back wall.
4.
Floor clearance: This inner chamber firebox floor must be installed at least 6" above any combustible flooring mate-
rial, such as carpeting or asphalt tile, which is closer than 14" to the base of the firebox. See Figure 5.
Or
The inner chamber firebox floor may be installed nearer to the floor if a minimum of 14" of noncombustible material
such as slate or marble is installed between the base of the firebox and the combustible flooring. See Figure 6.
Figure 5 - Minimum Clearance above
Combustible Flooring
8
HEIGHT REqUIREMENTS
Combustible
Material
6" Minimum
Figure 4 - Clearance and Height
Can Be
Less than 6"
14" Minimum
Figure 6 - Minimum Clearance above Combustible
Flooring with Non-Combustible Material Installed at
Base of Fireplace
4 2
M i
"
n i m
u m
6 "
M i
n i m
u m
M i
Requirements
Non-Combustible
Material
6 "
n i m
u m
26D4750