Quick-release trigger
MagnaClean Micro2 incorporates a secure, quick-release, trigger which enables the filter to be
removed and reinstalled in seconds. The connections enable easy and swift filter removal during
servicing or to undertake a MagnaCleanse system flush. This also makes it ideal for systems where
there is little room to install a filter.
The following instructions are designed to support engineers in the safe and effective servicing of
MagnaClean Micro2 using the quick-release trigger.
Note: Follow servicing steps 1, 2, 3 and 4 before following Quick-release trigger steps below.
4 1
Turn locking pin 90°
and remove.
4 4
Fit quick release
trigger and canister
onto valves.
4 2
Disconnect.
4 5
Replace locking pin
and turn 90° to lock.
4 3
Remove.
Clean collets and lubricate
seals with water.