Boiler door opening method
Figure 5.4. Use the zipper when closing boiler door of the combustion chamber
A
20
Detail A
Zipper
Technical instructions BioSolid
6.0. CONTROL OF BOILER TEMPERATURE
Pump of heating system P1 (see scheme 1 and 2) should be connected to boiler
control unit BioSolid which control pump operation and protects boiler against
subcooling.
6.1. BOILER CONTROL UNIT BioSolid
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
6.1.1. DESCRIPTION OF THE BUTTONS AND LABELS ON BOILER
CONTROL UNIT
Figure 4. Control panel of boiler control unit BioSolid
11
Fi10
Fi20
1
2
3
- ''0/1'' the main switch (power supply switch) has the function to turn on / off the
1
regulator.
- Indication "START" (LED diode) shows the regulator functioning mode-turn on.
2
- ''START / STOP" button - turn on / turn off the fan.
3
4
- "+" button.
5
- "SET" button.
6
- "-" button.
- Indication (LED diode) "NO FUEL" indicates that the temperature of the flue gases
7
is below the default value after defined elapsed time of fan work.
8
- Indication "FAN" (LED diode) indicates that the fan is turned on/off.
9
- Indication (LED diode) "Pump". indicates that the pump P1 is turned on/off.
- The LED display shows the measured temperatures, paramter settings and
10
detection of possible errors.
- safety thermostat -turn of the supply of electricity to the boiler and turn of boiler
11
control unit if temperature in boiler exceeds 110°C (+0°C / -9°C)
Technical instructions BioSolid
Boiler control unit
10
9
8
7
4
5
6
13