Majestic fireplaces VF Collection UVS36 Installations- und Betriebsanleitung für Hausbesitzer - Seite 3
Blättern Sie online oder laden Sie pdf Installations- und Betriebsanleitung für Hausbesitzer für Gas-Heizung Majestic fireplaces VF Collection UVS36 herunter. Majestic fireplaces VF Collection UVS36 20 Seiten. The vf collection vent-free gas fireplaces
Auch für Majestic fireplaces VF Collection UVS36: Spezifikationen (2 seiten)
This gas room heater should be installed by a qualified installer
in accordance with local building codes and with current Na-
tional Fuel Gas Code. ANSI Z223.1/NFPA 54.
"This heater shall not be installed in a confined space or
unusually tight construction unless provisions are provided for
adequate combustion and ventilation air".
"The National Fuel Gas Code, ANSI Z233.1/NFPA 54 defines
a confined space as a space whose volume is less than 50
cubic feet per 1,000 Btu per hour (4.8m
gregate input rating of all appliances installed in that space
and an unconfined space as a space whose volume is not less
than 50 cubic feet per 1,000 Btu per hour (4.8 m
aggregate input rating of all appliances installed in that space
and an unconfined space as a space whose volume is not less
than 50 cubic feet per 1,000 Btu per hour (4.8m
aggregate input rating of all appliances installed in that space..
Rooms communicating directly with the space in which the
appliances are installed, through openings not furnished with
doors, are considered a part of the unconfined space.
WARNING: If the area in which the heater may be operated is
smaller than that defined as an unconfined space of if the build-
ing is of unusually tight construction, provide adequate combus-
tion and ventilation air by one of the methods, described in the
National Fuel Gas Code, ANSI Z 223.1/NFPA 54, Section 5.3 or
applicable local codes."
Unusually tight construction is defined as construction where:
a) Walls and ceilings exposed to the outside atmosphere have
a continuous water vapor retarder with a rating of 1 perm (6
x 10-11 kg per pa-sec-m
) or less with openings gasketed or
2
sealed, and
b) Weather stripping has been added on openable windows
and doors, and
c) Caulking or sealants are applied to areas such as joints
around window and door frames, between sole plates and
floors, between wall-ceiling joints, between wall panels, at
penetrations for plumbing, electrical, and gas lines, and at other
openings.
Fireplace screen (when equipped) must be closed while
the appliance is in operation.
WARNING: Do not allow LP tank below 1/4 full.
WARNING: Do not allow fans to blow directly into the
fireplace. Avoid any drafts that alter burner flame pat-
terns.
WARNING: Do not use a blower insert, heat exchanger
or other accessory not approved for use with this
heater.
WARNING: Any change to this heater or its controls
can be dangerous.
This appliance may be installed in an aftermarket,
permanently located, manufactured (mobile home),
where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases.
20000135
Installation & Operating Instructions
per kw) of the ag-
3
3
per kw) of the
per kw) of the
3
Majestic Fireplaces
UVC / UVS Vent-Free Heaters
®
FOR SAFE INSTALLATION AND OPERATION OF YOUR VER-
MONT CASTINGS MAJESTIC PRODUCTS COMPANY VENT-
FREE ROOM HEATER PLEASE NOTE THE FOLLOWING:
1. This heater gives off high temperatures and should be
located out of high traffic areas and away from furniture and
draperies.
2. Children and adults should be alerted to the hazards of the
high temperatures surface of this heater and should stay
away to avoid burns or ignition of clothing.
3. Young children should be carefully supervised when they
are in the same room as your heater.
4. Under no circumstances should this heater be modified.
Parts removed for service should be replaced prior to oper-
ating this heater again.
5. Installation repair to this heater should be done by a quali-
fied service person. A professional service person should be
contacted to inspect this heater annually. Make it a practice
to have all of your gas heaters checked annually. More fre-
quent cleaning may be required due to excess lint and dust
from carpeting, bedding material, etc.
6. Control compartments, burners and air passages in this
heater should be kept clean and free of dust and lint. Make
sure that the gas valve and pilot light are turned off before
you attempt to clean this unit.
7. Under no circumstances should any solid fuels (wood, coal,
paper or cardboard, etc.) be used in this heater.
8. Keep the area around your heater clear of combustible ma-
terials, gasoline and other flammable vapor and liquids. This
heater should not be used as a drying rack for clothing, nor
should Christmas stockings or decorations be hung in the
area of it.
9. Whether the heater is installed directly on carpeting, vinyl
tile or any combustible material other than wood, this heater
must be installed on a metal or wood panel extending the
full width and depth of the heater.
10. Do not install heater in bedroom or bathroom.
11. Do not place clothing or other flammable material on or near
the appliance.
12. Any safety screen or guard removed for servicing an appli-
ance must be replaced prior to operating the heater.
13. Do not use this room heater if any part has been under
water.
This appliance is intended for supplemental heating.
WARNING: Do not install televisions or other elec-
tronic devices above this fireplace unless approved
by the electronics manufacturer.
Proposition 65 Warning: Fuels used in gas, wood-
burning or oil fired appliances, and the products of
combustion of such fuels, contain chemicals known to
the State of California to cause cancer, birth defects
and other reproductive harm.
California Health & Safety Code Sec. 25249.6
3