Burner CPPL-14
Burner CPPL-35
Technical instructions Cm Pelet-set
Pr06: Setting of burner output CPPL-14
Factory setting: P-2
Programme meaning: P-2 – 14 kW
Burner output is set by + and – buttons in
accordance with the boiler output.
Pr06: Setting of burner output CPPL-35
Factory setting: P-3
Programme meaning: P-3 20 kW
P-4 25 kW
P-5 30 kW
P-6 35 kW
Burner output has to be set by + and – buttons in
accordance with the boiler output.
Pr07:
Turning
on
(allowed to be used only if a room thermostat
is connected)
Factory setting: OFF (switched off)
Available settings: "On" (turned off) and "OFF"
(turned on).
If anti-frost programme is turned on by pressing
"+" button, and room thermostat is (obligatory)
set to minimum, control unit will monitor
temperature in the boiler and sanitary water tank
and when it drops below +5
on and heat boiler to T
set
Pr08: Service menu, PIN (code) entry (only for
servicemen)
Factory setting: OFF (switched off)
Available setting: Pin (switched on)
If "+" button is pressed, "Pin" appears in the lower
screen and PIN (enabling us to enter the service
menu for setting of burner parameters) can be
entered.
By SET button we exit Pr08.
Pr09: Service menu, PIN (code) entry (only for
servicemen)
Factory setting: OFF (switched off)
Available setting: Pin (switched on)
If "+" button is pressed, "Pin" appears in the lower
screen and PIN (enabling us to enter the service
menu for setting of burner parameters) can be
entered for the basic configuration software.
By SET button we exit Pr09.
anti-frost
programme
0
C, the burner will turn
.
10